6. Thread the cables through the eyebolts in the rear
wall. Return the cables through the holes near the
bottom corners of the convection box back panel (See
figure 16).
7. Place the convection box fully back into the fireplace
opening so that it is sealed against the fireplace front
surround.
8. Fit a cable retainer over the bottom end of each cable.
9. Pull each cable taut. Push the cable retainers hard up
against the back panel. Tighten the screws in the
retainers so that they clamp the cables in position. Apply
tension to the cables by turning the hexagonal adjusters
by hand (See figure 17).
10. Inspect the installation of the convection box against
Figure 16. Cable route
the fireplace surround. If the
convection box is aligned
squarely and the sealing is
satisfactory, fully tighten the cable
retainers.
11. If the convection box is not
correctly aligned, release the
tension on the cables by
slackening the screws and turning
the hexagonal adjusters fully
Figure 17. Lower cable retention
anticlockwise. The convection box
should then automatically realign
itself. Pull each cable taut again and push the cable retainers back against the back
panel. Again, tighten the screws in the retainers and apply tension to the cables by
turning the hexagonal adjusters clockwise as far as
possible.
12. Push the free length of the cables inside the
convection box so that they are available to allow
easy removal and refitting of the appliance during
subsequent service calls.

9.3 Floor sealing.

Using the floor sealing tape supplied, seal the
bottom of the convector box to the fireplace and
hearth floor (See figure 18).
Figure 18. Floor sealing
Page 26
©
Baxi Heating U.K. Limited 2010.