LED Display
Definition
The reactions of the
photocells/ safety
F3
edge/ loop detector
when they detecting
obstacles
Motor Speed
F4
Motor Force
F5
F6
Open Partially
F7
Pre-flashing
Deceleration point
F8
programming of total
travel distance
Deceleration speed
F9
The position of safety devices:
●
Safety Edge
Photocell
18
INSTRUCTIONS PL600/PL1000
Function
Value
F3-1
Please the function setting
F3-2
after F8
F3-3
F4-1
Slow
F4-2
Medium
F4-3
Fast
F4-4
Very Fast
Light
F5-1
Light
F5-2
F5-3
Light
F5-4
Light
F5-5
Light
F5-6
Light
F5-7
Light
F5-8
Light
F5-9
Light
F6-0
3 seconds
F6-1
6 seconds
F6-2
9 seconds
12 seconds
F6-3
15 seconds
F6-4
F6-5
18 seconds
The flashing light blinks
F7-0
when the gate starts to move.
The flashing light blinks 3
F7-1
seconds before the gate
starts to move.
75%
F8-0
80%
F8-1
85%
F8-2
90%
F8-3
95%
F8-4
F9-1
50% full speed
F9-2
25% full speed
Loop Detector
Photocell 1
Photocell 2
Description
1. Please the function setting after F
2. The factory setting is "F3-1".
1. The function can adjust the
running speed of motor.
2. The factory setting is "F4-4".
Heavy
1. The function can adjust the
Heavy
running force of motor to be
Heavy
compatible with the gate weight.
2. The factory setting is "F5-4".
Heavy
3. The motor force value:
F5-1: 2A
Heavy
F5-2: 3A
Heavy
F5-3: 4A
F5-4: 5A
Heavy
F5-5: 6A
Heavy
Heavy
1. The function can adjust the time
of opening partially.
2. The factory setting is "F6-1".
1. The factory setting is "F7-0".
1. The factory setting is "F8-0".
1. The factory setting is "F9-1".
Photocell 1
or
Photocell 1 / Photocell 2
8
F5-6: 7A
F5-7: 8A
F5-8: 10A
F5-9: 13A
Need help?
Do you have a question about the KIT PL600 and is the answer not in the manual?