6.2.7 PTO SWITCH _____________________________________________________________

The PTO switch is a 2-position knob type switch to engage and to disengage the mowers. The PTO
switch must be in the OFF (down) position to start the engine.
The 4WD switch must be in the ON position for the PTO switch to engage the mowers.
Pull on the red knob to move the switch to the ON position. When the PTO switch is in the ON
position, the cutting units are engaged. When the cutting units are lowered, the blades will start to
turn. When the cutting units are lifted, the blades will stop.

6.2.8 LIGHT SWITCH ____________________________________________________________

The light switch controls the operation of the lights.
Press the switch to the middle position to turn on the road lights.
Press the switch to the forward position to turn on the work lights.
Press the rear part of the switch to turn off the lights.
6.2.9 DPF LIGHT MODULE _______________________________________________________
The Diesel Particulate Filter (DPF) light module has a Regen Request light and High
Exhaust Temperature light that indicate the status of the DPF Regen system.
When a Parked Regen cycle is necessary, the front amber light will flash. During a
Parked Regen cycle, the Regen Request light will illuminate. See 9.10
The rear amber light indicates that an Active or Parked Regen cycle is active and a
high exhaust temperature is sensed. See 9.10
6.2.10 ENGINE LIGHT MODULE ___________________________________________________
The engine light module has an amber glow plug active light and a red check engine
light.
The front amber glow plug light indicates the glow plugs are active. Do not turn the
ignition switch to the start position until the glow plug light turns off.
The amber check engine light indicates that the engine controller sensed a problem.
Connect a CAN diagnosis tool or the Kubota Diagmaster tool to identify problem.
When the check engine light is illuminated, the DPF Regen cycle will not start.
NOTICE
CONTROLS 6
Regen
Request
High Exhaust
Temperature
Glow Plug
Check
Engine
en-32