overload

utility power present
1c
flashing
1g
on
1 beep every second
Pulsar switches off automatically after
operating in overload for approximately 5
min.
no utility power present
1c
flashing
1g
on
1 beep every second
Pulsar switches off automatically after a
length of time which depends on the level
of overload.
NOTE:
Overload occurs if the electricity
consumption of the load connected is
greater than the rated power of Pulsar.
To acknowledge the fault, push button
temporarily disconnected Pulsar from the
wall socket
5
, disconnect non-priority
loads and re-start Pulsar.
18
operating anomalies
device fault
1b
flashing
1g
on
1 beep every second
switch off Pulsar (push button
connect from the wall socket (flex
check that Pulsar has not short-circuited (dis-
connect all applications),
check the input fuse
with a fuse of the same rating or reset ther-
mal breaker 6 ,
re-start Pulsar.
utility power outside limits
1a
to
1g
...
continuous beep
after the start-up sequence, if the audio
warning device sounds continuously, check
the voltage and frequency of your utility
3
,
power (see the § entitled "characteristics")
and/or recharge your battery for 8 hours.
Pulsar ESV 8+/11+/14+/22+ EB 22/EB 22XLA : 86-153277-00
battery fault
A battery test is carried out while Pulsar, is in
start-up phase, then automatically every 7 days
(overhaul times adjustable using ESV Driver).
If a battery fault is detected, the following
occurs:
3
), dis-
5
), and
6b
and replace it
recharge your battery for 8 hours.
If battery fault persists, see next page.
Start/Stop control on onput
receptacles 1 and 2
off
(PowerShare)
You can use the applications included on
the CD-ROM to remote control the
Start/Stop sequences on output receptacles
7a (or 7b ). If 7a (or 7b ) is disabled
through software, front panel led 1f
(or 1e ) flashes, with 1 beep every second.
Beep can be deactivated by
"function" button 2 .
NOTE:
If the previous symptoms persist, contact
our after sales department.
1a
flashing
1g
on
1 beep every second
MGE UPS SYSTEMS