Connecting Modules And Devices - Bosch AMAX 2100 Quick Start Manual

Hide thumbs Also See for AMAX 2100:
Table of Contents

Advertisement

10
en | Connecting Modules and Devices
4

Connecting Modules and Devices

The AMAX panel provides BOSCH option bus 1 and option bus 2 (only for AMAX 3000 BE and
AMAX 4000) to connect modules and devices. Each module can be connected to each bus.
A maximum of 14 modules (8 keypads) can be connected to each bus.
The following overview displays the maximum number of modules that can be connected.
Module
Keypads
DX2010
DX3010
DX4010
GPRS module:
B450 with B442 or B443, DX4020-
G
IP module:
B426
RF receiver
Table 4.1: Maximum number of modules
How to connect a keypad and a RADION receiver:
1.
2.
3.
4.
2015.05 | 05 | F.01U.309.297
Connect the keypad to the option bus on the AMAX panel according to the wiring diagram
(refer to Graphics).
Connect the RFRC-OPT RADION receiver to the option bus on the AMAX panel according
to the wiring diagram (refer to Graphics).
Connect the red and black wires supplied with the battery to the AMAX panel and the
battery.
Connect the power adapter and battery to the mains.
AMAX 2100
4
-
1
1
Up to 2 different GPRS modules, each GPRS module can
only be connected once. Exception: 2 B450 modules can
be connected.
2 (1 if one of the GPRS modules above is connected, 0 if
two of the GPRS modules above are connected)
-
Quick Start Manual
AMAX 3000 /
AMAX 4000
3000 BE
8
16
3
6
2
1
Bosch Sicherheitssysteme GmbH
AMAX panel

Advertisement

Table of Contents
loading

This manual is also suitable for:

Amax 3000Amax 4000