GE NetworX NX-6V2 Installation And Startup page 37

Hide thumbs Also See for NetworX NX-6V2:
Table of Contents

Advertisement

EVEN NUMBERED .....
Contains the event code sent for Contact ID or SIA and chosen from the list on pg 16.
format is being used, the number programmed in this location will be sent as the upper hex digit. The digit should be
from 1 to 15 when using 4+2 formats. The zone ID or user ID will be the lower hex digit of the zone that is in alarm.
ODD NUMBERED
.......
The defaults listed below represent the five segments of each of those locations. Use the data from location 111
(worksheet on page 36 and instructions on pg 25)
LOC
112
ZONE TYPE 2 ALARM EVENT CODE
113
ZONE TYPE 2 CHARACTERISTIC SELECT
114
ZONE TYPE 3 ALARM EVENT CODE
115
ZONE TYPE 3 CHARACTERISTIC SELECT
116
ZONE TYPE 4 ALARM EVENT CODE
117
ZONE TYPE 4 CHARACTERISTIC SELECT
118
ZONE TYPE 5 ALARM EVENT CODE
119
ZONE TYPE 5 CHARACTERISTIC SELECT
120
ZONE TYPE 6 ALARM EVENT CODE
121
ZONE TYPE 6 CHARACTERISTIC SELECT
122
ZONE TYPE 7 ALARM EVENT CODE
123
ZONE TYPE 7 CHARACTERISTIC SELECT
124
ZONE TYPE 8 ALARM EVENT CODE
125
ZONE TYPE 8 CHARACTERISTIC SELECT
126
ZONE TYPE 9 ALARM EVENT CODE
127
ZONE TYPE 9 CHARACTERISTIC SELECT
128
ZONE TYPE 10 ALARM EVENT CODE
129
ZONE TYPE 10 CHARACTERISTIC SELECT
130
ZONE TYPE 11 ALARM EVENT CODE
131
ZONE TYPE 11 CHARACTERISTIC SELECT
132
ZONE TYPE 12 ALARM EVENT CODE
133
ZONE TYPE 12 CHARACTERISTIC SELECT
134
ZONE TYPE 13 ALARM EVENT CODE
135
ZONE TYPE 13 CHARACTERISTIC SELECT
136
ZONE TYPE 14 ALARM EVENT CODE
137
ZONE TYPE 14 CHARACTERISTIC SELECT
138
ZONE TYPE 15 ALARM EVENT CODE
139
ZONE TYPE 15 CHARACTERISTIC SELECT
140
ZONE TYPE 16 ALARM EVENT CODE
141
ZONE TYPE 16 CHARACTERISTIC SELECT
142
ZONE TYPE 17 ALARM EVENT CODE
143
ZONE TYPE 17 CHARACTERISTIC SELECT
144
ZONE TYPE 18 ALARM EVENT CODE
145
ZONE TYPE 18 CHARACTERISTIC SELECT
146
ZONE TYPE 19 ALARM EVENT CODE
147
ZONE TYPE 19 CHARACTERISTIC SELECT
148
ZONE TYPE 20 ALARM EVENT CODE
149
ZONE TYPE 20 CHARACTERISTIC SELECT
150
ZONE TYPE 21 ALARM EVENT CODE
151
ZONE TYPE 21 CHARACTERISTIC SELECT
152
ZONE TYPE 22 ALARM EVENT CODE
153
ZONE TYPE 22 CHARACTERISTIC SELECT
154
ZONE TYPE 23 ALARM EVENT CODE
155
ZONE TYPE 23 CHARACTERISTIC SELECT
156
ZONE TYPE 24 ALARM EVENT CODE
157
ZONE TYPE 24 CHARACTERISTIC SELECT
158
ZONE TYPE 25 ALARM EVENT CODE
159
ZONE TYPE 25 CHARACTERISTIC SELECT
160
ZONE TYPE 26 ALARM EVENT CODE
161
ZONE TYPE 26 CHARACTERISTIC SELECT
162
ZONE TYPE 27 ALARM EVENT CODE
163
ZONE TYPE 27 CHARACTERISTIC SELECT
164
ZONE TYPE 28 ALARM EVENT CODE
165
ZONE TYPE 28 CHARACTERISTIC SELECT
166
ZONE TYPE 29 ALARM EVENT CODE
167
ZONE TYPE 29 CHARACTERISTIC SELECT
168
ZONE TYPE 30 ALARM EVENT CODE
169
ZONE TYPE 30 CHARACTERISTIC SELECT
NX-6V2 Control
LOCATIONS 112 – 169
DESCRIPTION
DEFAULT
2
2-125-78-0-0
7
5-1245-5678-0-0
5
45-125-5678-0-0
5
457-125-5678-0-0
4
0-1245-5678-0-0
0
2-0-78-0-0
1
1-13-378-0-0
7
6-1245-5678-0-0
2
24-5-78-0-0
3
3-0-0-0-0
5
457-125-45678-0-0
4
0-12458-5678-0-0
7
5-12456-5678-0-0
5
457-1256-5678-0-0
4
0-12456-5678-0-0
7
5-1245-25678-0-0
5
457-125-25678-0-0
4
0-1245-25678-0-0
7
6-1245-25678-0-0
15
24-15-78
20
24-15-78
21
24-15-78
22
1-13-378
14
248-45-0-0-0
5
467-125-5678-0-0
5
457-1257-5678-0-0
7
6-12457-5678-0-0
5
457-125-5678-1-0
7
5-1245-5678-1-0
4+2 Format Note: If 4+2
PROGRAMMING DATA
__
__ __ __ __ __
__
__ __ __ __ __
__
__ __ __ __ __
__
__ __ __ __ __
__
__ __ __ __ __
__
__ __ __ __ __
__
__ __ __ __ __
__
__ __ __ __ __
__
__ __ __ __ __
__
__ __ __ __ __
__
__ __ __ __ __
__
__ __ __ __ __
__
__ __ __ __ __
__
__ __ __ __ __
__
__ __ __ __ __
__
__ __ __ __ __
__
__ __ __ __ __
__
__ __ __ __ __
__
__ __ __ __ __
__
__ __ __ __ __
__
__ __ __ __ __
__
__ __ __ __ __
__
__ __ __ __ __
__
__ __ __ __ __
__
__ __ __ __ __
__
__ __ __ __ __
__
__ __ __ __ __
__
__ __ __ __ __
__
__ __ __ __ __