GE NetworX NX-6V2 Installation And Startup page 32

Hide thumbs Also See for NetworX NX-6V2:
Table of Contents

Advertisement

LOC
PG
17
14
PHONE 3, SELECTING WHICH PARTITIONS REPORT TO PHONE 3
Segment 1
1 = Partition 1
2 = Partition 2
18
15
FORMAT OVERRIDE
Segment 1 (Circle Numbers To Program)
1 = ON - 1800hz transmit; OFF - 1900hz
2 = ON - 2300hz handshake; OFF - 1400hz.
3 = ON - cksum parity; OFF - double round parity
4 = ON - 2 digit event code; OFF - 1 digit code
5 = Reserved.
6 = Reserved.
7 = ON - 20 p.p.s.; OFF - 10 or 40 p.p.s.
8 = ON - 10 p.p.s.; OFF - 20 or 40 p.p.s.
Segments 3 & 4 RESERVED
L
19
15
DOWNLOAD ACCESS CODE
L
20
15
RINGS TO ANSWER DOWNLOAD
21
15
DOWNLOAD CONTROL
L
Segment 1
1 = Enables two call answering machine defeat
2 = Enables tone sniff answering machine defeat
3 = Requires callback before downloading
4 = Shutdown control panel
5 = Lock out local programming
6 = Lock out communicator programming
7 = Lock out download section
8 = Enables callback at autotest interval
22
15
CALLBACK PHONE NUMBER
L
L
23
15
PARTITION 1, FEATURE SELECTION
Segment 1
1 = Quick Arm
2 = Re-Exit
3 = Auto Bypass
4 = Silent Panic
Segment 2
1 = LED extinguish enable
2 = Require user code for bypassing zones
3 = Bypass sounder alert
4 = AC power/low battery sounder alert
Segment 3
1 = Open/Close
2 = Bypass
3 = Restore
4 = Trouble
Segment 4
1 = Late to Close / Early to Open
2 = Auto Arm in Stay Mode
3 = Disables door delays in Night mode
4-8 = Reserved
Segment 5 RESERVED
24
16
ENTRY / EXIT TIMERS
L
Segment 1 (Entry Time 1)
Segment 2 (Exit Time 1)
Segment 3 (Entry Time 2)
Segment 4 (Exit Time 2)
Segments 5 & 6
25
18
ZONES 1-8, ZONE TYPES
L
26
18
ZONES 1-8, PARTITION SELECTION (Segment 1=Zone 1 thru Segment 8=Zone 8)
Segments(Zone)
Partition 1
Partition 2
27
18
ZONES 9-16, ZONE TYPES
L
28
18
ZONES 9-16, PARTITION SELECTION (Segment 1=Zone 9 thru Segment 8=Zone 16)
Segments(Zone)
Partition 1
Partition 2
32
DESCRIPTION
(Circle Numbers To Program)
(Circle Numbers To Program)
(Circle Numbers To Program)
(Circle Numbers To Program)
(Circle Numbers To Program)
(Circle Numbers To Program)
1
2
1
1
2
2
1(9)
2(10)
1
1
2
2
DEFAULT
Segment 2 (Circle Numbers To Program)
1 = ON - pager format (no handshake required)
2 = ON - 1400/2300 handshake
3 = Reserved
4 = Reserved
5 = ON - Contact ID
6 = ON - SIA
7 = ON - Contact ID or 4+3
8 = ON - DTMF
8-4-8-0-0-0-0-0
8
14-14-14-14-14-14-14-14-14-14-
14-14-14-14-14-14-14-14-14-14
5 = Audible Panic
6 = Auxiliary 1
7 = Auxiliary 2
8 = Multi Keypress Tamper
5 = Enables bypass toggle
6 = Enables silent auto arm
7 = Enables automatic instant
8 = Enables Instant mode toggle
5 = Tamper
6 = Cancel
7 = Recent Closing
8 = Exit Error
30
60
30
60
Reserved
3-5-6-6-6-6-6-6
3
4
1
1
2
2
6-6-6-6-6-6-6-6
3(11)
4(12)
5(13)
1
1
2
2
PROGRAM DATA
_ _ _ _ _ _ _ _
_
__ __ __ __ __ __ __ __ __ __
__ __ __ __ __ __ __ __ __ __
_ _ _ _ _ _ _ _
5
6
7
1
1
1
2
2
2
_ _ _ _ _ _ _ _
6(14)
7(15)
1
1
1
2
2
2
8
1
2
8(16)
1
2
NX-6V2 Control

Advertisement

Table of Contents
loading

Table of Contents