Segment 1:
Program a "1" if the interval is to be in hours; Program a "0" if in days. Add a A2" to suppress the daily test or a A3" to
suppress the hourly test if any report has been sent.
Segment 2:
Program the Autotest interval from 1-255 hours/days.
Segment 3:
Program the Autotest report hour in 24-hour format (if the interval is in hours, this segment is ignored).
Segment 4:
Program the Autotest report time, number of minutes after the hour.
52
Location 52 contains the time in 24 hour format the NX-6V2 enables codes designated as arm only after closing. This time is only valid
on those days programmed in location 54. Note: Opening time must be earlier than closing time for Auto Arm, Aux. Outputs, or Code
Authorization to function properly.
Segment 1:
Program the hour of the opening time.
Segment 2:
Program the minutes after the hour of the opening time.
53
Location 53 contains the time in 24 hour format the NX-6V2 disables the disarm capability for codes designated as arm only after
closing. This is also the time the Automatic Arming sequence will begin (if enabled in location 55)..
Segment 1:
Program the hour of the closing / auto arm time.
Segment 2:
Program the minutes after the hour of the closing / auto arm time.
54
Location 54 selects which days of the week each partition is open. On these days, Aarm only after close window@ codes will be able to
arm and disarm during open window. NOTE: If any partition is not programmed to be opened and is programmed to Auto-Arm
(Location 55), the NX-6V2 will try to arm every 45 minutes for the duration of the closed period unless Auto Retry is disabled
in location 55. On days not selected here, Aarm only after close window@ codes will not disarm. Segment 1 is for partition 1, and
segment 2 is for partition 2. (See locations 52 and 53 for the opening and closing times for the open days.)
Segment 1-2:
1 = Open on Sunday.
2 = Open on Monday.
3 = Open on Tuesday.
4 = Open on Wednesday.
5 = Open on Thursday.
6 = Open on Friday.
7 = Open on Saturday.
8 = Reserved.
55
Location 55 selects which days each partition will auto arm. Segment 1 is for partition 1, and segment 2 is for partition 2. If a zone is
faulted when the panel tries to auto arm, the zone will be bypassed.
Segments 1-2:
1 = Auto Arming on Sunday.
2 = Auto Arming on Monday.
3 = Auto Arming on Tuesday.
4 = Auto Arming on Wednesday.
5 = Auto Arming on Thursday.
6 = Auto Arming on Friday.
7 = Auto Arming on Saturday.
8 = Disable 45 minute retry timer.
22
AUTOTEST CONTROL
OPENING TIME
CLOSING TIME/AUTOMATIC ARMING TIME
DAYS OF WEEK EACH PARTITION IS OPEN
DAYS OF WEEK EACH PARTITION WILL AUTO ARM
4 ............ numerical
2 ............ numerical
2 ............ numerical
2 ............ feature select
2 ............ feature select
NX-6V2 Control