LOC
PG
73
24
GROUND FAULT / GROUND FAULT RESTORE
74
24
EXPANDER TROUBLE / EXP TROUBLE RESTORE
75
24
FAILURE TO COMMUNICATE
76
24
LOG FULL COMMUNICATOR CODE
77
24
OPENING CODE COMMUNICATOR CODE
Segment 1: Partition 1 Opening Code
Segment 2: Partition 2 Opening Code
78
24
CLOSING COMMUNICATOR CODE
Segment 1: Partition 1 Closing Code
Segment 2: Partition 2 Closing Code
79
24
AUTOTEST COMMUNICATOR CODE
80
24
RECENT CLOSING AND EXIT ERROR
81
24
START PROGRAMMING / END PROGRAMMING
82
24
END DOWNLOAD
83
24
CANCEL COMMUNICATOR CODE
84-87
24
RESERVED
88
25
PARTITION 1, ACCOUNT CODE
89
25
PARTITION 2, ACCOUNT CODE
90
25
PARTITION 2, FEATURE AND REPORTING SELECTION
Segment 1
1 = Quick Arm
2 = Re-Exit
3 = Auto Bypass
4 = Silent Panic
Segment 2
1 = LED extinguish enable
2 = Require user code for bypassing zones
3 = Bypass sounder alert
4 = AC power/low battery sounder alert
Segment 3
1 = Open/Close
2 = Bypass
3 = Restore
4 = Trouble
Segment 4
1 =Late to Close / Early to Open
Segment 5 Reserved
91
25
PARTITION 2 ENTRY/EXIT TIMERS
Segment 1: Entry Time 1
Segment 2: Exit Time 1
Segment 3: Entry Time 2
Segment 4: Exit Time 2
Segment 5 & 6 Reserved
92- 109
25
RESERVED
110
25
ZONE TYPE 1 ALARM EVENT CODE
111
25
ZONE TYPE 1 CHARACTERISTIC SELECT
Segment 1
1 = Fire (enable for fire zone)
2 = 24-Hour (enable for non-fire 24 hour)
3 = Keyswitch zone
4 = Follower (
instant during non-entry times
Segment 2
1 = Keypad audible on alarm.
2 = Yelping siren on alarm.
3 = Temporal siren on alarm.
4 = Chime.
Segment 3
1 = Fast Loop Response.
2 = Double End of Line Tamper zone.
3 = Trouble zone (Day zone).
4 = Cross Zone.
Segment 4
1 = Zone Activity Monitor.
2 = End of Line Resistor Defeat.
3 = Enables zone to act as request to exit
input / disables for alarm activation.
Segment 5 RESERVED
36
DESCRIPTION
enable for burg zones that are
)
DEFAULT
0-0-0-0
0-0-0-0
0-0
0-0
0
0
0
0
0-0
0-0
0-0-0-0
0-0-0-0
0
0-0-0-0
10-10-10-10-10-10
10-10-10-10-10-10
5 = Audible Panic
6 = Auxiliary 1
7 = Auxiliary 2
8 = Multi Keypress Tamper
5 = Enables bypass toggle
6 = Enables silent auto arm
7 = Enables auto instant
8 = Reserved
5 = Tamper
6 = Cancel
7 = Recent Closing
8 = Exit Error
2-8 =Reserved
0
0
0
0
8
5 = Delay 1 zone (enable to follow Timer 1 Entry/Exit times)
6 = Delay 2 zone (enable to follow Timer 2 Entry / Exit times)
7 = Interior (Enable for auto bypass or stay arming)
8 = Local Only (enable if zone is not to be reported)
5 = Bypassable.
6 = Group Shunt.
7 = Force armable.
8 = Entry Guard.
5 = Dialer Delay zone.
6 = Swinger zone.
7 = Restore reporting.
8 = Listen-In.
4 = Enables zone to act as access entry point (
segment unless configured with Access Control.
5-8 = Reserved.
PROGRAMMING DATA
_ _ _ _
_ _ _ _
_ _
_ _
_
_
_
_
_ _
_ _
_ _ _ _
X X _ _
_
Reserved
_ _ _ _ _
_ _ __ _ _
_
_
_
_
_
Do not enable this
)
NX-6V2 Control