KEYPAD SOUNDER CONTROL
Segment 1 (Circle numbers to program)
1 = Keypad sounds for Telephone Line Cut when in the Armed state.
2 = Keypad sounds for Telephone Line Cut when in the Disarmed state.
3 = Keypad sounds upon AC Power Failure.
4 = Keypad sounds upon Low Battery Detection.
5 = Keypad sounds during Cross Zone Trip Time.
6 = Keypad sounds for Tamper Alarm.
7 = Reserved.
8 = Keypad sounds for expander trouble (required for UL).
L
40
19
SYSTEM TIMERS
Segment 1 Dynamic Battery Test duration (0-255 minutes)
Segment 2 AC Failure report delay (0-255 minutes)
Segment 3 Power Up Delay (0-60 seconds)
Segment 4 Siren Time (1-254 minutes)
Segment 5 Telephone Line Cut delay (0-255 seconds)
Segment 6 Cross Zone Time (0-255 minutes)
Segment 7 Chime Time in 50 mS increments (0-255)
Segment 8 Dialer delay (15-255 seconds)
Segment 9 Fire Alarm Verification Time (120-255 sec.)
Segment 10 Listen-In Time (0-255 seconds)
Segment 11 Zone Monitor Timer (0-255 Days)
Segments 12 – 14 Reserved
41
20
SPECIAL FEATURES
Segment 1 (Circle numbers to program)
1 = Enables 6-digit code option. All arm/disarm/Go To Program codes require six digits.
2 = Requires valid user code entry for [r]-[9]-[8] and [r]-[9]-[9] functions to work.
3 = Enable Auto Cancel / Abort.
4 = Enable Walk-Test Mode.
5 = Enables Auto Force-Arming with keyfob or keyswitch
6-8=Reserved. (Do not program!)
42
20
GO TO PROGRAM CODE
L
43
20
GO TO PROGRAM CODE PARTITION AND AUTHORIZATION
Segment 1 (Circle numbers to program)
1 = Reserved.
2 = Enables "Go To Program Code" as an arm only code.
3 = Enables "Go To Program Code" as an arm only after closing.
4 = Enables "Go To Program Code" as a master arm/disarm code (can change user codes)
5 = Enables "Go To Program Code" as an arm/disarm code.
6 = Enables "Go To Program Code" to bypass zones.
7 = Enables "Go To Program Code" opening and closing reports.
8 = Reserved.
Segment 2 (Circle numbers to program)
1 = Enables "Go To Program Code" for partition 1
2 = Enables "Go To Program Code" for partition 2
44
20
DURESS CODE
L
45
20
AUXILIARY OUTPUTS 1-4 PARTITION SELECTION
Segments (Aux Out)
1 = Partition 1
2 = Partition 2
46
21
AUXILIARY OUTPUTS 1-4 SPECIAL TIMING
Segments (Aux Out)
1 = Aux output timed in minutes.
2 = Aux output to latch.
3 = Aux output to stop timing upon user code entry.
4 = Aux output to activate only between closing & opening time.
5 = Aux output to activate only between opening & closing time.
6 = Invert auxiliary output (0 Volts going to 12V when activated).
7 = Reserved
8 = Reserved
47
21
AUXILIARY OUTPUT #1, EVENT & TIME
Segment 1: Event number for output # 1
Segment 2: Timing for output # 1
48
21
AUXILIARY OUTPUT #2, EVENT & TIME
Segment 1: Event number for output # 2
Segment 2: Timing for output # 2
34
DESCRIPTION
DEFAULT
0
5
60
8
0
5
3
30
0
0
0
9-7-1-3-0-0
15-15-15-15-15-15
1
1
2
1
1
2
3
4
5
6
7
8
0=Burglary alarm
10 seconds
1=Fire alarm
10 seconds
PROGRAM DATA
_
_
_
_
_
_
_
_
_
_
_
_ _ _ _ _ _
_ _ _ _ _ _
2
3
4
1
1
1
2
2
2
2
3
4
1
1
1
2
2
2
3
3
3
4
4
4
5
5
5
6
6
6
7
7
7
8
8
8
NX-6V2 Control

Advertisement

Table of Contents
loading

Table of Contents