Dip Switch Settings And Locations; Control Board Dip Switch; Feed Head Board Dip Switch; Devicenet/Gateway Board Dip Switch, Bank (S1 - Lincoln Power Wave 455 Operator's Manual

Table of Contents

Advertisement

A-10

DIP Switch Settings and Locations

DIP switches on the P.C. Boards allow for custom
configuration of the Power Wave. To access the DIP
switches:
WARNING
• Turn off power at the disconnect switch.
------------------------------------------------------------------------
• Remove the top four screws securing the front
access panel.
• Loosen, but do not completely remove, the bottom
two screws holding the access panel.
• Open the access panel, allowing the weight of the
panel to be carried by the bottom two screws. Make
sure to prevent the weight of the access panel from
hanging on the harness.
• Adjust the DIP switches as necessary.
• Replace the panel and screws, and restore power.
Control Board
Left
DeviceNET/Gateway Board

Control Board DIP Switch:

switch 1 = Object Instance LSB 1 (see table 1)
switch 2 = Object Instance MSB 2 (see table 1)
switch 3 = Equipment Group 1 Select
switch 4 = Equipment Group 2 Select
switch 5 = Equipment Group 3 Select
switch 6 = Equipment Group 4 Select
switch 7 = reserved for future use
switch 8 = work sense lead
1 LEASE SIGNIFICANT BIT
2 MOST SIGNIFICANT BIT
switch 8 work sense lead
off
work sense lead not connected
on
work sense lead connected
INSTALLATION
Feed Head Board
Right
POWER WAVE 455/R

Feed Head Board DIP Switch:

switch 1 = Object Instance LSB (see table 1)
switch 2 = Object Instance MSB (see table 1)
switch 3 = Equipment Group 1 Select
switch 4 = Equipment Group 2 Select
switch 5 = Equipment Group 3 Select
switch 6 = Equipment Group 4 Select
switch 7 = negative polarity switch
switch 7
electrode polarity
off
positive (default)
on
negative
switch 8 = high speed gear
switch 8
wire drive gear
off
low speed gear (default)
on
high speed gear
DeviceNET/Gateway Board DIP Switch:
Bank (S1):
switch 1 = Object Instance LSB (see table1)
switch 2 = Object Instance MSB (see table 1)
switch 3 = Equipment Group 1 Select
switch 4 = Equipment Group 2 Select
switch 5 = Equipment Group 3 Select
switch 6 = Equipment Group 4 Select
switch 7 = Reserved for future use
switch 8 = Reserved for future use
TABLE 1
Object Instance
switch 2
switch 1
off
off
off
on
on
off
on
on
A-10
Instance
0 (default)
1
2
3

Hide quick links: