B-4

CASE FRONT CONTROLS

All operator controls and adjustments are located on
the case front of the Power Wave. (See Figure A.4)
1. POWER SWITCH: Controls input power to the
Power Wave.
2. STATUS LIGHT: A two color light that indicates
system errors. Normal operation is a steady green
light. Error conditions are indicated, per table 4.
NOTE: The robotic Power Waves' status light will
flash green, and sometimes red and green, for up to
one minute when the machine is first turned on. This
is a normal situation as the machine goes through a
self test at power up.
TABLE 4
Light
Condition
Steady Green
System OK. Power source communicating normal-
ly with wire feeder and its components.
Blinking
Occurs during a reset, and indicates the PW-
Green
455/R is mapping (identifying) each component
in the system. Normal for first 1-10 seconds
after power is turned on, or if the system con-
figuration is changed during operation.
A l t e r n a t i n g
Non-recoverable system fault. If the PS
Green
and
Status light is flashing any combination of
Red
red and green, errors are present in the PW-
455/R. Read the error code before the
machine is turned off.
Error Code interpretation through the Status
light is detailed in the Service Manual.
Individual code digits are flashed in red with
a long pause between digits. If more than
one code is present, the codes will be sepa-
rated by a green light.
To clear the error, turn power source off, and
back on to reset. See Troubleshooting
Section.
Steady Red
Not applicable.
Blinking Red
Not applicable.
OPERATION
Meaning
POWER WAVE 455/R
3. HIGH TEMPERATURE LIGHT (thermal overload):
A yellow light that comes on when an over temper-
ature situation occurs. Output is disabled until the
machine cools down. When cool, the light goes out
and output is enabled.
4. 10 AMP WIRE FEEDER CIRCUIT BREAKER:
Protects 40 volt DC wire feeder power supply.
5. 10 AMP AUXILIARY POWER CIRCUIT BREAKER:
Protects 115 volt AC case front receptacle
auxiliary supply.
6. LEAD CONNECTOR S2 (SENSE LEAD)
7. 5-PIN ARC LINK S1
8. 5-PIN DEVICENET CONNECTOR S5
9. I / O CONNECTOR
10. NEGATIVE STUD
11. INTERFACE CONNECTOR S6
12. STT STUD
13. POSITIVE STUD
14. AUXILIARY OUTPUT
FIGURE A.4
POWERWAVE
6
7
8
9
-
10
5
Case Front Layout
Power Wave 455/R (Domestic/Canadian Version)
B-4
3
2
1
11
12
+
13
14
4

Hide quick links: