Installation; Technical Specifications - Power Wave 455/R - Lincoln Power Wave 455 Operator's Manual

Table of Contents

Advertisement

A-1
TECHNICAL SPECIFICATIONS - POWER WAVE 455/R (K1761-1),(K1761-2)
INPUT VOLTS
(K1761-1)
208/230/460V - 60HZ.
200/220/440V - 50HZ.
(K1761-2)
208/230/460/575V-60HZ.
208/230/460/575V-50HZ.
OPEN
CURRENT
CIRCUIT
RANGE
VOLTAGE
75 VDC
5 - 570
PROCESS CURRENT RANGES (DC)
MIG/MAG
RECOMMENDED INPUT WIRE AND FUSE SIZES FOR MAXIMUM RATED OUTPUT
INPUT
VOLTAGE /
FREQUENCY
(HZ)
(K1761-1)
208/50/60
230/50/60
460/50/60
(K1761-2)
208/50/60
230/50/60
460/50/60
575/50/60

INSTALLATION

INPUT AT RATED OUTPUT - THREE PHASE ONLY
OUTPUT
INPUT
CONDITIONS
CURRENT
70/65/35
450A@38V.100%
570A@43V. 60%
87/82/48
400A@36V.100%
72/67/36
500A@40V. 60%
79/74/41
450@38V.100%
58/53/25/22
570@43V.60%
82/78/37/31
400@36V.100%
49/45/23/18
500A@40V. 60%
67/61/31/25
PULSE
PULSE
FREQUENCY
VOLTAGE
RANGE
0.15 - 1000 Hz
5 - 55 VDC
FCAW
SMAW
Pulse
STT
TYPE 75°C
COPPER WIRE IN CON-
DUIT AWG[IEC] SIZES
(MM2)
4 (25)
4 (25)
8 (10)
4 (25)
4 (25)
8 (10)
10 (6)
POWER WAVE 455/R
IDLE
POWER
AMPS
400 Watts
Max.
OUTPUT
PULSE AND
BACKGROUND
TIME RANGE
100 MICRO SEC. -
3.3 SEC.
TYPE 75°C
GROUND WIRE IN CON-
DUIT AWG[IEC] SIZES
(MM2)
6 (10)
6 (10)
10 (6)
6 (10)
6 (10)
10 (6)
10 (6)
POWER FACTOR
EFFICIENCY
@ RATED OUPUT
@ RATED OUPUT
.89 MIN.
.95 MIN.
STT PARAMETERS
AUXILIARY POWER
(CIRCUIT BREAKER
PROTECTED)
40-325 AMPS
40 VDC @10 AMPS
115VAC @10 AMPS
CURRENT
50-570 Average Amps
40-570 Average Amps
30-570 Average Amps
5-750 Peak Amps
40-325 Average Amps
TYPE 75°C
(SUPER LAG)
OR BREAKER
SIZE (AMPS)
A-1
88%
110
110
50
110
100
50
40

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Power wave 455r

Table of Contents