Errors; Advices - RIKA Rikatronic4 Operating Manual

Hide thumbs Also See for Rikatronic4:
Table of Contents

Advertisement

6. ERRORS

Note
The fault indicator will
flash
red.
For recurring error messages the customer service must be informed immediately!
Display
Fo3
Fo4
Fo6
Fo7
Fo8
Note
If an error message occurs, remove first the reason and then acknowledge the error by pressing the function button more than 2 seconds.

7. ADVICES

Tip
These displays only appear briefly when you press a button or when the child safety lock was activated.
Display
HOT
Meaning
The automatic ignition failed.
The air flaps cannot be completely closed.
The combustion chamber door is open for
more
than
three
minutes
The door contact switch is defective.
The temperature sensor measures wrong values.
The temperature sensor is defective.
The air flap motor cannot reach the specified
position.
Meaning
The selected function cannot be executed because
the stove temperature is too high.
A selected function cannot be executed because
the combustion chamber door is open.
The display is locked, the child-lock is activated.
Actions to be taken
Repeat the ignition process, possibly add more
chipboard or an entire block of fire lighters.
Check chimney draft.
Use dry wood.
Check to see if anything is blocking the air
flaps, check the function of the electric lifting
magnet (when activated you can hear a
"clack").
The combustion chamber door may only be
during
heating.
opened briefly to refill during heating. Close the
door again immediately.
Check the function of the switch: ease of
contact, audible clunk while pressing.
Check if the temperature sensor is very dirty
or sooty and clean it carefully (see CLEANING
AND MAINTENANCE).
Check to see if anything is blocking the air
flaps.
Actions to be taken
Allow the stove to cool down to room
temperature, then select the desired function
(for example air flaps close)
Close combustion chamber door!
This should only be opened briefly to add more
fuel.
Press the Plus and Menu buttons simultaneously
to unlock.
The confirmation of the cancellation takes place
with the short display UNLOCK.
|9
8

Advertisement

Table of Contents
loading

Table of Contents