8. MANUAL OPERATION

Power failure
During a power failure, the air supply remains unchanged, the logs in the
combustion chamber burn down safely. If the mains supply is restored, stove
name and software version are displayed shortly. Then the display WAIT
(Component test - up to 4 minutes) appears.
A possibly entered ignition time must be activated again.

Manual control

Note
Manual operation is only allowed when the stove is off the grid. Another
approach than the below mentioned may damage the components and lead
to a loss of warranty.
Disconnect the stove by switching off the main power switch.
Q
Insert the supplied wrench in the place provided.
Q
Turn the wrench clockwise until you sense a stop.
Q
Note
Caution, excessive force can cause damage.
Pull the wrench from the socket and plug it into a horizontal position again.
Q
You are in heating-up position.
Turn the wrench a few minutes after a successful ignition phase
Q
counterclockwise in vertical position. You are now in the medium position.
Turn the wrench counterclockwise gradually to reduce the combustion air by
Q
hand and therefore regulate the combustion process by hand.
Note
Always make sure that the stove has enough air for the combustion,
otherwise it may lead to an increased smoke development and subsequently
to a deflagration!