15.8 Solar
(option available only with external module CAN)
15.8.1 State
15.8.2 Settings
Function
Turn on delta
Turn off delta
15.8.3 Service
Function
Schematic
Flow [l/min]
Fluid specifi c heat
MAX HW temp.
Solar alarm temp. MAX
Solar alarm temp MIN
Solar pump test
Temp. diff erence between solar and accumulator needed for
solar pump turn on.
Temp. diff erence between solar and accumulator needed for
solar pump turn off .
Solar system schematic.
Heating fl uid fl ow in l/min.
Specifi c heat of heat-transfer fl uid [kJ/ (kg*K)].
Over this hot water temp. solar pump is turn off .
Maximal temp. of solar collector. Alarm and damage
preservation procedure are taken over this temp.
Minimal temp. of solar collector. Alarm and antifreeze
procedure are taken under this temp.
Allow for solar pump testing.
Description
Description
47