12.1.3 Graphic display

12.2. Statuses of furnace

Status
TURNED OFF
CLEANING
FIRING UP
INCANDESCING
POWER 1
POWER 2
MODULATION
BURNING OFF
Stop
The burner is not working. Permission to work off .
Cleaning the burner by strong stream of air.
Firing up fuel. Providing the initial dose of fuel to run
igniter and blower.
When the fl ame in phase of the fi ring up is discovered,
starts providing additional portions of fuel and
increase the power of blower for arcing furnace.
The burner works with the power fi rst.
The burner works with the power of a second.
The burner works with a modulated power.
Quenching of the furnace. Work of burner and blower
tray until the complete disappearance of the fl ame.
Burner does not work but it is to agree to his work.
The required boiler temperature is reached.