Safe Distance To Inflammable Substances - Orlanski ORLIGNO 400 Instruction Manual & Service Manual

Table of Contents

Advertisement

10.4. Safe distance to inflammable substances

- During installation and exploitation it is advisable to maintain safe distance of 200 mm from inflammable
substances
- For inflammable substances with C3 grade of combustibility which rapidly and easy burn (ex. paper,
cardboard, wood, plastic) distance is minimum 400 mm;
- If combustibility grade is unknown safe distance should be doubled.
Combustibility grade of building products
A – non-burning
B - hard burning
C1- hard burning
C2 – middle burning
C3 – easy burning
User please remember:
- Only adult person acquainted with this manual may operate the burner It is forbidden for kids to stay in
close distance to burner without presence of adult person.
- If inflammable gases penetrate boiler room during activities (varnishing, gluing) it is recommended to
turn off the burner.
- It is forbidden to use inflammable substances for lightning up the burner, burner will light up
automatically.
- High risk of fire exist when using open fire or inflammable substances close to installed boiler package.
- Burner should be turned off during maintenance (position OFF).
- Pay attention on hot burner's surfaces – risk of burn.
- It is forbidden to lay inflammable items on the burner or nearby.
- All defects should be removed at once.
- After heating season it is recommended to clean the burner and pellet tank thoroughly.
- Oversee the burner during power failure
- It is forbidden to manipulate with any electric parts or interfere in burner's construction.
16
Building products
sandstone, concrete, bricks, fire plaster, Mortar, tile,
granite
cement board, fiberglass, mineral insulation
beech tree, oak tree, plywood
pine, larch, spruce tree, cork, rubber floor cover
tarmac plywood, celuloids, polyurethane, Polystyrene,
polyethylene, plastic

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents