Basic Distributed I/O Interface; LOCAL Control

Note: RA to Digital Input #1 jumper removed.
RS-485
1:Reserved
2:EV
3:GND
4:SG-
5:SG+
6:Reserved
RC
7:Reserved
8:Reserved
Digital Input
Digital Input
Digital Input
Digital Input
Digital Input
Digital Input
Digital Common
+24 VDC / 20 mA
ANL Common
ANL In 0-10 VDC / 47 kΩ
ANL In 4-20 mA / 250 Ω
+10 VDC / 3 mA
ANL Out; 0-10 VDC / 2 mA / 20 kΩ
Opto-Out Common
Opto-Out; Max 48 VDC / 50 mA
The Powerfoil
X2.0 fan is programmed to be controlled via the included wall controller, which starts, stops, and performs speed
®
control duties for the fan. Fault messages and toggling between output frequency and fan RPM displays are also controlled by the wall
controller. This mode of operation is commonly referred to as "local control."
*For the wall control unit to be active, the LOC indicator light must be illuminated by pressing the LOCAL/REM button.
8'–24' POWERFOIL
X2.0 WASHDOWN & POWERFOIL
®
Electrical Installation (cont.)
RA
RB
MI1
MI2
MI3
MI4
MI5
MI6
DCM
DCM
24V
ACM
AVI
ACI
10V
AFM
MCM
M01
WWW.BIGASSFANS.COM
X2.0 PLUS WASHDOWN
®
FWD / STOP
REV / STOP
Required 0-10VDC
Analog Speed Reference
Optional 0-10VDC
Analog Speed
Feedback
Optional Drive Fault
Status Output
48V @ 50mA Max.
©2012 DELTA T CORP.
ALL RIGHTS RESERVED
F
H
U
RUN
STOP
FWD
REV
REM
LOC
LOCAL
MODE
REM
FWD
PROG
REV
DATA
STOP
RUN
RESET
LOCAL / REMOTE
TOGGLE
"REM" indicator is Lit
37