Wiring: Fan Motor - BIG ASS FANS powerfoil x2.0 Installation Manual

Washdown
Hide thumbs Also See for powerfoil x2.0:
Table of Contents

Advertisement

34

Wiring: Fan Motor

WARNING: Wait three minutes after disconnecting before servicing!
WARNING: Improper installation can cause electric shock or damage to the motor and controller! A qualified electrician
should perform the installation.
The diagrams below show wiring for low voltage and high voltage systems. These diagrams include L2 and L3 swap to yield proper
motor rotation. Motors with terminal blocks require ring terminals and a 7mm nut driver for termination.
Consult the motor wiring nameplante or wiring placard for verification of required wiring connections. See pages 2–3 for detailed
voltage, current, and circuit breaker/fuse requirements.
U2
T4
U5
T7
U1
T1
BLACK
BLUE
RED
Low Voltage
8'–24' POWERFOIL
X2.0 WASHDOWN & POWERFOIL
®
Electrical Installation (cont.)
Low Voltage
200–240 VAC, 50–60 Hz
330–350 VAC, 50–60 Hz
V2
W2
T5
T6
V5
W5
T8
T9
V1
W1
T2
T3
Low Voltage
200–240 VAC, 50–60 Hz
330–350 VAC, 50–60 Hz
T1 – BLU
T7 – PNK
T2 – WHT
T8 – RED
T3 – ORG
T9 – GRY
T4 – YEL
T5 – BLK
T6 – VLT
WWW.BIGASSFANS.COM
X2.0 PLUS WASHDOWN
®
U2
T4
U5
T7
U1
T1
BROWN
YELLOW
ORANGE
High Voltage
©2012 DELTA T CORP.
ALL RIGHTS RESERVED
High Voltage
400–480 VAC, 50–60 Hz
575–600 VAC, 50–60 Hz
V2
W2
T5
T6
V5
W5
T8
T9
V1
W1
T2
T3
High Voltage
400–480 VAC, 50–60 Hz
575–600 VAC, 50–60 Hz
T1 – BLU
T2 – WHT
T3 – ORG
T4 – YEL
T7 – PNK
T5 – BLK
T8 – RED
T6 – VLT
T9 – GRY