Symptom #3 - Remote Condenser - Manitowoc Indigo Series Technician's Handbook

Air/water/remote condenser ice machines
Hide thumbs Also See for Indigo Series:
Table of Contents

Advertisement

SYMPTOM #3 - REMOTE CONDENSER

Traditional Remote Ice Machine - Long Harvest/Low Production/Intermittent Safety Limit 2
START
Normal ice fill, long harvest cycle,
Fails at night or in low
NO
possible SL #2, back of cubes are
ambient - Operates
not melted at the end of harvest cycle
normally above 70F/21C
YES
YES
Liquid Line
Wet condenser
Temperature Warm
with water during
(body temperature)
freeze cycle
Discharge line temperature
is normal at the end of the
NO
freeze cycle?
Liquid Line Temperature Cool
All Remotes = >150F/65C
Liquid Line
Replace Headmaster
Temperature Hot
Refer to Symptom
#2 - Freeze Cycle
YES
Analysis Chart
System low on refrigerant