SAFETY LIMIT #2

Harvest time exceeds 3.5 minutes for 500 consecutive
harvest cycles
Possible Cause Checklist
Improper Installation
Refer to "Installation/Visual Inspection Checklist"
page 135
Water System
Water area (evaporator) dirty
Dirty/defective water dump valve
Vent tube not installed on water outlet drain
Water freezing behind evaporator
Plastic extrusions and gaskets not securely
mounted to the evaporator
Clogged water distribution tube
Electrical System
Ice thickness probe out of adjustment
Bin switch closed/defective
Premature harvest
Refrigeration System
Non-Manitowoc components
Improper refrigerant charge
Defective head pressure control valve
Defective harvest valve
TXV flooding (check bulb mounting)
Defective fan cycling control
Water cooled only - Water regulating valve is
incorrectly adjusted or will not close during harvest
cycle.