J. Ps Roller - Toshiba e-STUDIO203S Service Manual

Hide thumbs Also See for e-STUDIO203S:
Table of Contents

Advertisement

(3) Paper empty sensor removal
1) Disconnect one connector.
2) Remove the paper empty sensor.
1

J. PS roller

(1) Parts removal
1) Remove the gear.
2) Remove the pulley.
3) Remove the belt.
2
3
1
(2) Parts removal
1) Remove one screw.
2) Remove the earth wire.
3) Remove the E-ring.
4) Remove the bearing.
5) Open the scan plate.
4
5
■ Note for reassembly
Pass the earth wire through the hole to the outside of the frame,
then install parts.
2
2
1
4
3
e-STUDIO203S/203SD DISASSEMBLY AND ASSEMBLY 8 - 26
(3) Scan plate removal
1) Remove the scan plate.
1
(4) PS roller removal
1) Remove the PS roller.
K. Upper transport roller
(1) Parts removal
1) Remove the gear.
2) Remove the upper transport release arm.
3) Remove the bearing.
4) Remove the E-ring.
5) Remove the bearing.
2 3
1
■ Note for reassembly
Use care so that the rib on the upper transport release arm catches
the guide.
1
5 4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-studio203sd

Table of Contents