5) Remove the cleaning blade.
Note: Dispose the cleaning blade which was removed.
If a cleaning error occurs, replace the cleaning blade.
(Recommendable replacement cycle: Every 25K)
6) Clean the cleaning section and the waste toner pipe to remove
waste toner completely with a vacuum cleaner.
7) Remove the felt and duplex tape completely.
Note: Be careful not to scratch or bend the sub blade.
8) Attach the cleaning blade.
Securely insert the plate section of the cleaning blade into the
unit and fix it with a screw.
Do not touch the cleaning blade rubber with your hand.
When attaching the cleaning blade, press the cleaning blade in
the arrow direction and attach.
e-STUDIO203S/203SD DISASSEMBLY AND ASSEMBLY 8 - 2
9) Attach the felt.
0 – 0.3 mm
Moquette R
0 – 0.5 mm
Moquette R
Sub blade
Be careful not to allow the
moquette to cover the sub blade.
Example of NG
Attach the mocket with slightly pressing section A of the clean-
ing blade.
Do not touch the tip of the cleaning blade.
Do not put the mocket under the cleaning blade.
Do not put the mocket on the sub blade.
Do not press the sub blade with the mocket.
If the moquette F/R is deformed or damaged, replace it. (Rec-
ommendable replacement cycle: Every 25K)
10) Attach the main charger.
Securely set the MC holder on the projection of the process
frame.
Securely insert two projections of the MC holder into the groove
in the process frame.
When attaching the MC holder ass'y, be careful not to make
contact with the cleaning blade.
: Check while pressing the blade.
Cleaning blade
0 – 0.3 mm
Moquette F
Sub blade
0 – 0.5 mm
Cleaning blade
Moquette F