C. DV blade
1) Peel off the old DV blade.
2) Clean the attachment surface with alcohol.
3) Attach the new DV blade to the reference position.
DV blade IC
DV-BOX AS
D. DV doctor
1) Remove the screw, and remove the DV doctor.
* Clean the edge (A) section.
1)
A
2)
■ Note for installation
1) Insert the DG check gauge as shown in the figure.
2) After checking, install the doctor gap and fix it with a screw.
* Apply screw lock to the screw tightening section as shown in the
figure below.
MG-ROL
* After checking the DG,
apply screw lock.
FRONT
F
1
20
10
DG check
position
DG check
gauge
A
B
A
0.5
0
1)
DG check
gauge
REAR
C
R
10
20
2
110
DG check
DG check
gauge
gauge
e-STUDIO203S/203SD DISASSEMBLY AND ASSEMBLY 8 - 21
E. DV sensor
1) Remove the Mylar.
2) Remove the screw, and remove the DV sensor.
* Clean the sensor (A) section.
2)
B
10. Duplex motor section
(e-STUDIO203SD only)
A. List
No.
Part name Ref.
1
Duplex motor
B. Disassembly procedure
1) Remove the rear cabinet.
2) Remove two screws.
3) Remove the Duplex motor cover.
4) Remove the Duplex motor.
Note: When reassembling, be sure to engage the Duplex motor
gear with the belt on the main body side.
C. Assembly procedure
For assembly, reverse the disassembly procedure.