Device fan

Device fan
Device fan
2.8.3
2.8.3
Device fan
Device fan
The system comes with two 28 mm * 40 mm (15500 rpm) device fans.
Refer to the illustration below for location of the device fans.
To uninstall the device fan:
1.
Disconnect the device fan cable
from the connector on the
motherboard or backplane board.
2.
Lift the fan, then set aside.
To reinstall the device fan:
1.
Insert the fan to the fan cage.
The airflow directional arrow on
the fan side should point towards
the rear panel.
2.
Connect the device fan cable to
the fan connector on the
backplane board or on the
motherboard.