bora PT11UMEN-000 Operating And Installation Instructions page 14

Table of Contents

Advertisement

Installation
EN
>105
5
37
Fig. 5.9 Drilling template
[1]
Worktop
[2]
Fixed front panel
Pre-drill the bore holes to prevent tearing out the fixed
X
X
front panel.
Determine the number of adjustment plates
The total dimensions of the adjustment plates [2] and
Q
Q
the fixed front panel [3] should be 36 mm.
The total dimensions of 36 mm must be adhered to in
Q
Q
order to ensure that the control box [1] functions
smoothly.
Panel
Total
thickness
thickness
[mm]
of adjust-
ment
plates
[mm]
34
2
33
3
32
4
31
5
30
6
29
7
28
8
27
9
26
10
25
11
24
12
23
13
22
14
21
15
20
16
19
17
18
18
17
19
16
20
15
21
14
22
13
23
Tab. 5.3: Adjustment plate overview
14
5
Ø6
Ø30
90
Adjustment plates [quantity]
10 mm 5 mm
3 mm
-
-
-
-
-
1
-
-
-
-
-
1
-
-
2
-
1
-
-
1
1
-
1
-
1
-
-
-
1
2
1
-
-
1
-
1
1
-
-
1
1
-
1
-
2
1
1
-
1
1
1
1
1
-
1
1
1
1
1
2
1
1
1
1
1
2
Secure the control box
1
Position the control box [1] with the attached
X
X
2
adjustment plates [2] from the back into the bore
holes in the fixed front panel.
Attach the two power level sleeves [4] to the front
X
of the fixed front panel.
Fig. 5.10 Tighten the fixing nuts
Screw on the fixing nuts [5] with the mounting bracket
X
X
and tighten the fixing nuts with max. 10 Nm.
Insert the lens from the front into the power level
X
X
sleeve.
Put on the control knob [6].
X
Adjust the control knob
2 mm
For fine adjustment, the distance between the control
knob and the power level sleeve can be set.
1
-
2
1
-
1
-
2
-
-
1
-
2
Fig. 5.11 Position control knob
-
-
1
-
2
1
-
2
1
Fig. 5.12 Distance of the control knob
18,5 mm