Rated peak power
*The system input requirements are based on measurements using hardware available at the publication of this
document. For updated information, see the HP website (http://www.hp.com/go/proliant-energy-efficient).
Power supply specifications
The following specifications provide information on the parameters of the power supplies as they were
designed. For more information on configuring power for a specific server, see the HP website
(http://www.hp.com/go/proliant-energy-efficient).
Depending on installed options, the server is configured with one of the following power supplies:
•
HP ProLiant 460 W Power Supply
Specification
Input requirements
Rated input voltage
Rated input frequency
Rated input current
Rated input power
BTUs per hour
Power supply output
Rated steady-state power
Rated peak power
•
HP ProLiant 750 W Power Supply
Specification
Input requirements
Rated input voltage
Rated input frequency
Rated input current
Rated input power
BTUs per hour
Power supply output
Rated steady-state power
For more information, see "Power
supply specifications (on page
98)."
Value
100V to 120V AC
200V to 240V AC
50Hz to 60Hz
5.5A at 100V AC
2.6A at 200V AC
526 W at 100V AC input
505 W at 200V AC input
1794 at 100V AC input
1725 at 200V AC input
460 W at 100V to 120V AC input
460 W at 200V to 240V AC input
460 W at 100V to 120V AC input
460 W at 200V to 240V AC input
Value
100V to 120V AC
200V to 240V AC
50Hz to 60Hz
8.9A at 100V AC
4.3A at 200V AC
857 W at 100V AC input
824 W at 200V AC input
2925 at 100V AC input
2812 at 200V AC input
750 W at 100V to 120V AC input
750 W at 200V to 240V AC input
Specifications 98