Hard Drive Numbering - HP ProLiant DL385 G7 Maintenance And Service Manual

Hide thumbs Also See for ProLiant DL385 G7:
Table of Contents

Advertisement

Systems Insight Display
LED and color
DIMM (amber)
DIMM (amber)
Overtemperature (amber)
Fan (amber)
Power supply (amber)
Power supply (amber)
Power supply (amber)

Hard drive numbering

SFF device bay numbering
Health LED color Status
Red
DIMM in slot X has failed.
Amber
DIMM in slot X is in a pre-failure condition.
Red
One or more DIMMs have failed. Test each bank of DIMMs
by removing all other DIMMs. Isolate the failed DIMM by
replacing each DIMM in a bank with a known working
DIMM.
Amber
The Health Driver has detected a cautionary temperature
level.
Red
The server has detected a hardware critical temperature
level.
Amber
One fan is failed or removed.
Red
Two or more fans have failed or are missing.
Red
Only one power supply is installed and is in standby.
Power supply fault
System board fault
Amber
Redundant power supply is installed and only one power
supply is functional.
AC power cord not plugged into redundant power
supply
Redundant power supply fault
Amber
Power supply mismatch at POST or power supply mismatch
through hot add