LED and color
DIMM (amber)
DIMM (amber)
Overtemperature (amber)
Fan (amber)
Power supply (amber)
Power supply (amber)
Power supply (amber)
Hard drive numbering
•
SFF device bay numbering
Health LED color Status
Red
DIMM in slot X has failed.
Amber
DIMM in slot X is in a pre-failure condition.
Red
One or more DIMMs have failed. Test each bank of DIMMs
by removing all other DIMMs. Isolate the failed DIMM by
replacing each DIMM in a bank with a known working
DIMM.
Amber
The Health Driver has detected a cautionary temperature
level.
Red
The server has detected a hardware critical temperature
level.
Amber
One fan is failed or removed.
Red
Two or more fans have failed or are missing.
Red
Only one power supply is installed and is in standby.
•
Power supply fault
•
System board fault
Amber
Redundant power supply is installed and only one power
supply is functional.
•
AC power cord not plugged into redundant power
supply
•
Redundant power supply fault
Amber
Power supply mismatch at POST or power supply mismatch
through hot add