Pci Riser Cage Leds - HP ProLiant DL385 G7 Maintenance And Service Manual

Hide thumbs Also See for ProLiant DL385 G7:
Table of Contents

Advertisement

Online/activity
LED (green)
Flashing regularly
(1 Hz)
Flashing regularly
(1 Hz)
Flashing irregularly Amber, flashing
Flashing irregularly Off
Off
Off
Off

PCI riser cage LEDs

CAUTION:
remove all AC power cords before removing or installing the PCI riser cage.
Status
On = AC power is connected.
Off = AC power is disconnected.
Missing = Riser is not installed and power might be connected.
Fault/UID LED
Interpretation
(amber/blue)
Amber, flashing
Do not remove the drive. Removing a drive may terminate the
regularly (1 Hz)
current operation and cause data loss.
The drive is part of an array that is undergoing capacity expansion
or stripe migration, but a predictive failure alert has been received
for this drive. To minimize the risk of data loss, do not replace the
drive until the expansion or migration is complete.
Off
Do not remove the drive. Removing a drive may terminate the
current operation and cause data loss.
The drive is rebuilding, erasing, or it is part of an array that is
undergoing capacity expansion or stripe migration.
The drive is active, but a predictive failure alert has been received
regularly (1 Hz)
for this drive. Replace the drive as soon as possible.
The drive is active, and it is operating normally.
Steadily amber
A critical fault condition has been identified for this drive, and the
controller has placed it offline. Replace the drive as soon as
possible.
Amber, flashing
A predictive failure alert has been received for this drive. Replace
regularly (1 Hz)
the drive as soon as possible.
Off
The drive is offline, a spare, or not configured as part of an array.
To prevent damage to the server or expansion boards, power down the server and