Rated peak power
HP ProLiant 1200 W Power Supply
Specification
Input requirements
Rated input voltage
Rated input frequency
Rated input current
Rated input power
BTUs per hour
Power supply output
Rated steady-state power
Rated peak power
HP ProLiant 1200 W DC Power Supply
Specification
Input requirements
Rated input voltage
Rated input frequency
Rated input current
Rated input power
BTUs per hour
Power supply output
Rated steady-state power
Rated peak power
750 W at 100V to 120V AC input
750 W at 200V to 240V AC input
Value
100V to 120V AC
200V to 240V AC
50 Hz to 60 Hz
9.3A at 100V AC
6.6A at 200V AC
912 W at 100V AC input
1294 W at 200V AC input
3110 at 100V AC input
4413 at 200V input
800 W at 100V AC input
900 W at 120V AC input
1200 W at 200V to 240V AC
input
800 W at 100V AC input
900 W at 120V AC input
1200 W at 200V to 240V AC
input
Value
-36V to -72V DC
-48V DC, nominal input
Not applicable
38A at -36V DC
19A at -72V DC
28A at -48V DC, nominal input
1380 W at -36V DC input
1365 W at -72V DC input
1350 W at -48V DC, nominal
input
4713 at -36V DC input
4662 at -72V DC input
4610 at -48V DC, nominal input
1200 W
1200 W
Specifications 99