Mercury SC1000 User Manual page 31

System tach/speedometer and smart tow tachometer
Table of Contents

Advertisement

TACHOMETER CALIBRATION
1. Press and hold the "MODE/SELECT" and "+" buttons for
approximately seven seconds until the "CAL 1" screen
appears.
2. Press the "-" or "+" button to select the option choice displayed
in the [ ] brackets on the screen.
3. Press "MODE/SELECT" ["SAVE"] to save the setting and
advance through the calibration screens.
Tachometer CAL 1 Calibration - Remote Light and Contrast
REMOTE SCREENS ?
[ NO ]
[SAVE]
REMOTE LCD LIGHT ?
[ NO ]
[SAVE]
REMOTE LCD CONTRAST ?
[ NO ]
[SAVE]
Tachometer CAL 1 Calibration - Trim
HIGH RESOLUTION TRIM ?
[ NO ]
[SAVE]
TRIM POPUP ?
[ NO ]
[SAVE]
CALIBRATION 1
TRIM CALIBRATION
[SKIP]
If "YES" is selected, then screen changes made
on this tachometer will effect all tachometers in
the system. All tachometers need the screen set
[ YES ]
to "YES" for this function to work.
23620
Adjusts the lighting levels on all gauges
simultaneously from this gauge. If "YES" is
selected, then lighting levels changes made on
this tachometer will effect all tachometers in the
[YES ]
system. All tachometers need the screen set to
23532
Adjusts the contrast of another System/Smart
Tow Tachometer simultaneously from this
gauge. If "YES" is selected, then contrast level
changes made on this tachometer will effect all
[YES ]
tachometers in the system. All tachometers
23533
need the screen set to "YES" for this function to
Enables the trim angle to be displayed in 0.1°
increments if "YES" is selected.
[ YES ]
23621
The trim display screen pops up when the trim
setting is changed if "YES" is selected.
[ YES ]
23641
Select "EDIT" to calibrate the gauge to the
standard 0 - 10° unit trim and 11 - 25° trailer
position scale. Select "SKIP" to advance to the
[EDIT]
23910
27
"YES" for this function to work.
work.
next selection.