4. Using a standard flat head screwdriver release 1/4 turn quick-lock fasteners
(labeled 1, 2, 3, and 4) of the backside lamp sheet and remove it carefully. These
fasteners will remain connected to the lamp socket cover.
5. Gently remove the old lamp from it's socket. If the old lamp has exploded be sure
to remove all of the old lamp fragments to prevent damage to the internal
components.
6. Insert the new lamp securely, locking the
lamp in place as illustrated in the diagram
to the left. Orientate the lamp filler tube
towards the backside of the reflector.
Before reassembling the unit, be sure the
new lamp is securely seated in the lamp
socket. Always be sure to only use
specified lamp types!
7. Gently replace the lamp socket assembly in to place and secure with the four
quick release fasteners.
8. Be sure to reset the lamp running time in the "TIME" menu. The lamp run time is
designed to function as lamp replacement reminder (see page 25).
9. Final step would be to properly optimize the lamp. Follow the steps below to
properly align the lamp and inside the reflector.
Attention:
Be sure the lamp is securely seated in the lamp socket. Failure to comply
with this warning may cause excessive heat build-up that may cause the
internal lens to crack.

Lamp Optimization:

You should adjust the lamp position after each lamp replacement. This is necessary
due to the fact that every lamp has small manufacturing variations. The Power Spot
7000CMY II includes a lamp optimization system, consisting of two setscrews on the
back lamp socket cover (set screw A and B). The lamp adjustment is a matter of the
users taste but will best be done as follows: