PP117 - Safety Information
A minimum distance of 5 m between the unit and spray gun is to
be maintained.
When working outdoors:
Vapors containing solvents may not be allowed to blow toward
the unit.
Note the direction of the wind.
Set the unit up in such a way that vapors containing
solvents do not reach the unit and build up there.
A minimum distance of 5 m between the unit and
spray gun is to be maintained.
Danger
Ventilation when spraying in rooms
U
Adequate ventilation must be guaranteed for the removal of the
solvent vapors.

Suction installations

U
These are to be set-up by the user of the unit according to local
regulations.
Earthing of the object
U
The object to be coated must be earthed.

Components and Description

The shipping carton for your painting system contains the following:
• Suction tube and return tube
• Inlet filter
• Spray gun with two filters
Figure 1 - Controls and Functions
Item
Component
A)
ON / OFF Switch ............................The ON/OFF switch turns the power to the sprayer on and off (O=OFF, l=ON).
B)
PRIME / SPRAY Knob ....................The PRIME/SPRAY knob directs fluid to the spray hose when set to SPRAY or the return tube when set
C)
Quickflo™ Valve .............................The Quickflo™ valve is designed to keep the inlet valve open and from sticking to dried materials.
D)
PressureTrac™ ................................The PressureTrac™ regulates the amount of force the pump uses to push the fluid.
E)
Pump Section .................................A piston in the pump section moves up and down to create the suction that draws fluid through the
F)
Suction Tube ..................................Fluid is drawn through the suction tube into the pump.
G)
Return Tube ....................................Fluid is sent back out through the return tube to the original container when PRIME/SPRAY knob is in
H)
Inlet filter ..........................................The inlet filter strains the spray material to prevent the system from becoming clogged.
I)
Spray Gun ........................................The spray gun controls the delivery of the fluid being pumped.
J)
Spray Hose ......................................The spray hose connects the gun to the pump.
to PRIME. The arrows on the PRIME/SPRAY knob shows the rotation directions for PRIME and SPRAY.
The PRIME/SPRAY knob is also used to relieve pressure built up in the spray hose (see Pressure Relief
Procedure).
The Quickflo™ valve is activated manually by the user.
suction tube.
PRIME position.
Cleaning units with solvents
U
Danger
Cleaning the unit
U
Danger
Work or repairs on the electrical
U
equipment
Only have this work carried out by a qualified electrician. No liability
will be taken for incorrect installation.
Working on electrical components
U
Remove the mains plug from the socket for all such works.
• Spray tip assembly
• 7.5 m, 6.35mm diameter pressure hose
• Instruction manual
Description
12
When cleaning the unit with solvents, the solvent
should never be sprayed or pumped back into a
container with a small opening (bunghole). An
explosive gas/air mixture can be produced. The
container must be earthed.
Danger of short circuit through penetrating water!
Never spray down the unit with high-pressure or
high-pressure steam cleaners.