Specifications - Chamberlain CSW24U Installation Manual

Vehicular swing gate operator
Hide thumbs Also See for CSW24U:
Table of Contents

Advertisement

SPECIFICATIONS

This model is intended for use in vehicular swing gate applications:
Usage Classification
Main AC Supply
System Operating Voltage
Accessory Power
Solar Power Max
Maximum Gate Weight/Length
90 Degree Travel Time*
Maximum Travel Range*
Maximum Daily Cycle Rate
Maximum Duty Cycle
Operating Temperature
Expansion Board
Inherent Entrapment Protection (Type A)
External Entrapment Protection (Type B1 and/or Type B2)
*Travel time and range are affected by A and B mounting dimensions
INTRODUCTION
Class I, II, III, & IV
120 Vac, 4 Amps (10 Amps including Accessory Outlets)
OR
240 Vac, 2 Amps
24 Vdc Transformer Run / Battery Backup
24 Vdc, 500mA max. for ON + SW (switched)
24 Vdc at 60 watts max.
1200 lbs. (544.3 kg)/12 foot (3.7 m)
800 lbs. (362.9 kg)/16 foot (4.9 m)
600 lbs. (272.2 kg)/18 foot (5.5 m)
20 seconds
115 degrees
Continuous
Continuous
Without Heater: -20°C to 60°C (-4°F to 140°F)
With Optional Heater: -40°C to 60°C (-40°F to 140°F)
Provided
Dual - RPM and Current Sense
3 inputs per board - any combination of up to 3 photoelectric sensors and up to
2 edge sensors
27.66"
18.77"
6
14.8"

Hide quick links: