Operation; Gate Operator Setup Examples - Chamberlain CSW24U Installation Manual

Vehicular swing gate operator
Hide thumbs Also See for CSW24U:
Table of Contents

Advertisement

GATE OPERATOR SETUP EXAMPLES

The following are example setups for the gate operator. Your specific site requirements may be different. Always setup the operator system to the site
requirements, including all necessary entrapment protection devices.
RESIDENTIAL: One to four residential homes sharing a gated entrance/exit, allowing vehicle access trumps security concerns
COMMERCIAL/GENERAL ACCESS: A residential community (more than four homes) having one or more gated entrances/exits, allowing
vehicle access trumps security concerns
COMMERCIAL: Business site where security (gate closed) is important
INDUSTRIAL: Large business site where security is required
Setting
RESIDENTIAL
Quick Close switch
Normally set to OFF. Normal
setting
gate close (timer or control).
AC Fail Open switch
Normally set to BATT. Run on
setting
battery if AC power fails.
Low Battery switch
Normally set to OPEN. If
setting
powered from battery and
battery is low, gate
automatically opens and stays
open.
Anti-Tail switch
Normally set to OFF. CLOSE
setting
EYES/Interrupt loop reverses
a closing gate.
Bipart Delay switch
For DUAL-GATE site, set to
setting
ON for gate that delays upon
opening.
Aux Relay Out –
Typically not required.
Open Limit Switch
Aux Relay Out –
Typically not required.
Close Limit Switch
Aux Relay Out –
Attach alert signal (audible or
Gate Motion
visual alert system).
Aux Relay Out –
Attach alert signal (audible or
Pre-Motion Delay
visual alert system).
Aux Relay Out –
Attach visual alert to know
Power
when system is charging
batteries (i.e. not running on
batteries).
Aux Relay Out –
Attach alert signal (audible or
Tamper
visual alert system) to
(Slide Gates Only)
indicate if gate is manually
tampered with by being
pushed off of close limit.
Cycle Quantity
Use during servicing only to
Feedback
determine operator cycles.
Fire Dept Open
Typically not required.
input
Heater Accessory
The heater keeps the gearbox
(Model HTR)
and batteries at a suitable
temperature when the outside
temperature is below -4°F.
The thermostat MUST be set
between 45°F and 60°F to
ensure proper gate operation.

OPERATION

COMMERCIAL/GENERAL
ACCESS
Normally set to OFF. Normal gate
close (timer or control).
Normally set to BATT. For local
jurisdiction requirement, set to OPEN
so that the gate will open
approximately 15 seconds after AC
power fail.
Normally set to OPEN. If powered
from battery and battery is low, gate
automatically opens and stays open.
Normally set to OFF. CLOSE EYES/
Interrupt loop reverses a closing gate.
For DUAL-GATE site, set to ON for
gate that delays upon opening.
Use with SAMS (Sequence Access
Management System).
Typically not required.
Attach alert signal (audible or visual
alert system).
Attach alert signal (audible or visual
alert system).
Attach visual alert to know when
system is charging batteries (i.e. not
running on batteries).
Attach alert signal (audible or visual
alert system) to indicate if gate is
manually tampered with by being
pushed off of close limit.
Use during servicing only to determine
operator cycles.
Connect emergency access system
(Knox box switch, SOS system, etc.).
The heater keeps the gearbox and
batteries at a suitable temperature
when the outside temperature is below
-4°F. The thermostat MUST be set
between 45°F and 60°F to ensure
proper gate operation.
27
COMMERCIAL
Normally set to OFF. Normal gate
close (timer or control).
Normally set to BATT. Run on
battery if AC power fails.
Normally set to CLOSE. If
powered from battery and
battery is low, gate stays closed.
Set to ON. In attempt to prevent
vehicle tail-gating, CLOSE EYES/
Interrupt loop pauses a closing
gate.
For DUAL-GATE site, set to ON
for gate that delays upon
opening.
1) Use with SAMS (Sequence
Access Management System).
2) Connect "Gate Open" indicator
(e.g. light).
Connect "Gate Close/Secure"
indicator (e.g. light).
Attach alert signal (audible or
visual alert system).
Attach alert signal (audible or
visual alert system).
Attach visual alert to know when
system is charging batteries (i.e.
not running on batteries).
Attach alert signal (audible or
visual alert system) to indicate if
gate is manually tampered with
by being pushed off of close
limit.
Use during servicing only to
determine operator cycles.
Typically not required.
The heater keeps the gearbox
and batteries at a suitable
temperature when the outside
temperature is below -4°F. The
thermostat MUST be set between
45°F and 60°F to ensure proper
gate operation.
INDUSTRIAL
Set to ON, so that gate closes
immediately after vehicle passes
CLOSE EYES/Interrupt loop.
Normally set to BATT. Run on
battery if AC power fails.
Normally set to CLOSE. If
powered from battery and battery
is low, gate stays closed.
Set to ON. In attempt to prevent
vehicle tail-gating, CLOSE EYES/
Interrupt loop pauses a closing
gate.
For DUAL-GATE site, set to ON
for gate that delays upon opening.
1) Use with SAMS (Sequence
Access Management System).
2) Connect "Gate Open" indicator
(e.g. light).
Connect "Gate Close/Secure"
indicator (e.g. light).
Attach alert signal (audible or
visual alert system).
Attach alert signal (audible or
visual alert system).
Attach visual alert to know when
system is charging batteries (i.e.
not running on batteries).
Attach alert signal (audible or
visual alert system) to indicate if
gate is manually tampered with
by being pushed off of close limit.
Use during servicing only to
determine operator cycles.
Typically not required.
The heater keeps the gearbox and
batteries at a suitable temperature
when the outside temperature is
below -4°F. The thermostat MUST
be set between 45°F and 60°F to
ensure proper gate operation.