5. The count needs adjustment.
a. Please see below for adjustments.
NO.
1
2
3
4
5
6
Adjusting the Counter Sensor
Throught beam
Fix VR(Coarse) at ON
position with turning right
Initial setting
slowly when it is the status
of the recviced light.
Fix VR(Coarse) at ON position
Received light
with turning right slowly when it
is the status of the recviced
light.
Turning VR(Fine) until it is
Received light
OFF toward(-),and turning until
it is ON toward(+) again ,then
confirm that this will be A
position.
And then turning VR(Fine) until it
Interrupted light
is ON toward(+),and turning until
it is OFF toward(-) again in state
of shading light.Then confirm
that this position will be B
position.(when it will not be
ON.max. position will be B.
Fix it at middle of A and B
position.
This will be the best position
to set.
Received light
If it cannot adjust as above
method. set
max. position toward(+),then
execute again.
Adjusting
Coarse
Min.
ON
Min.
Coarse VR is
not required to
adjust
afterwards.
VR(Fine) at
Min.
13
VR
Fine
(-)
(+)
(-)
(+)
ON
A
OFF
(-)
(+)
OFF
B
ON
(-)
(+)
A
B
(-)
(+)
(-)
(+)
Max.