4.1 Connection to the mains

Verify the power supply settings before applying power!
If you wish to change the power supply settings,see the chapter below.
Connect the fixture to the mains with the power cord.
If the plug on the flexible cord is not the right type for your socket outlets,do not use an adaptor,but remove the
plug from the cord and discard.Carefully prepare the end of the the supply cord and fit a suitable plug.
The earth has to be connected!
The occupation of the connection-cables is as follows:
Cable (EU)
Brown
Light blue
Yellow/Green

4.2 Changing the power supply settings

Both the transformer and the ballast must be connected correctly for the local AC voltage and frequency.
The wrong settings can cause poor performance or demage of the fixture.The factory settings are printed next
to the power switch.
If you want to change the power supply settings,follow the instructions:
1.Disconnect the fixture from AC power.
2.Remove the top base covers by loosening the 10 fastening screws.
3.Move the wire 1 on the transformer connection block to the position according to the desired voltage.
4.Close the base before applying AC power.
Examples:
EU-version:
AC 230V/50Hz

4. Installation

Cable (US)
Pin
Black
Live
White
Neutral
Green
Earth
6
International
L
N
US-version:
AC120V/60Hz