Advertisement

Quick Links

Version 1.9 US

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ArcSource Outdoor 16 MC Integral RGBW US and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Robe ArcSource Outdoor 16 MC Integral RGBW US

  • Page 1 Version 1.9 US...
  • Page 2: Table Of Contents

    ArcSource Outdoor 16 MC Integral US Table of contents 1. Safety instructions ..............................3 2. Fixture exterior view ..............................5 3. Installation .................................. 5 3.1 Mounting the fixture ............................5 3.2 Top hat (Half top hat ) installation ........................6 3.3 Connection to the mains ............................
  • Page 3: Safety Instructions

    ArcSource Outdoor 16 MC Integral US FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE POWERING OR INSTALLING YOUR ArcSource Outdoor 16 MC Integral US ! Save it for future reference. This device has left our premises in absolutely perfect condition. In order to maintain this condition and to ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual.
  • Page 4 ArcSource Outdoor 16 MC Integral US Avoid brute force when installing or operating the fixture. The fixture was designed for outdoor use. This fixture must not be used for underwater installation. When choosing the installation spot, please make sure that the fixture is not exposed to extreme heat or dust. Avoid using the unit in locations subject to possible impacts.
  • Page 5: Fixture Exterior View

    ArcSource Outdoor 16 MC Integral US 2. Fixture exterior view 1. LED unit 2. Control unit 3. Antenna (only wireless DMX version) 4. Tilt adjusting locks 5. „U“ bracket 6. Control board with anti-vandal cover 7. Power/Data cable 8. LED unit connecting cable 3.
  • Page 6: Top Hat (Half Top Hat ) Installation

    ArcSource Outdoor 16 MC Integral US Ensure that the structure to which you are attaching the fixture is secure Caution: Overhead installation requires experience. Fixtures may cause severe injuries when crashing down! If you have doubts concerning the safety of a possible installation, do not install the device and consult installation with an expert.
  • Page 7: Connection To The Mains

    ArcSource Outdoor 16 MC Integral US 3.3 Connection to the mains Fixtures must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulation. This device falls under class one and must be grounded! The ArcSource Outdoor 16 MC Integral US is equiped with with a 5-cored power/data cable.
  • Page 8 ArcSource Outdoor 16 MC Integral US Connect the junction box acording to the tables below Power connection Braun Blue Green/yellow Black White Green DMX connection Data + Data ground(shielding) Data - Remove end caps from cable glands before passing cables into the junction box. The four cable glands M20 with standard seals serve for cable of diameter of 6-12mm, for smaller diameter of cable (4-8mm) you have to remove original sealing from the cable gland M20 and use the enclosed reducing seal instead it.
  • Page 9 ArcSource Outdoor 16 MC Integral US The junction box allows to connect several fixtures in a daisy chain of the power/data cable. Use the 3 x 1.5mm power cable to connect the first junction box with the mains and the power/data cable for connecting fixtures each other.
  • Page 10: Wireless Dmx Operation

    ArcSource Outdoor 16 MC Integral US 4. Wireless DMX operation The wireless version of the ArcSource Outdoor 16 MC Integral US is equipped with the Lumen Radio CRMX module and antenna for receiving DMX signal. CRMX module operates on the 2.4 GHz band. To link the fixture with the DMX transmitter Select option “Wireless“...
  • Page 11: Arcsource Outdoor 16 Mc Integral Us (Rgbw) - Dmx Protocol

    ArcSource Outdoor 16 MC Integral US 5. ArcSource Outdoor 16 MC Integral US (RGBW) - DMX protocol Version 1.1 Mode/Channel Value Function Type of control Red LEDs 0 - 255 Red LEDs saturation control (0-100%) proportional Green LEDs 0 - 255 Green LEDs saturation control (0-100%) proportional Blue LEDs...
  • Page 12: Arcsource Outdoor 16 Mc Integral Us (Rgba) - Dmx Protocol

    ArcSource Outdoor 16 MC Integral US 6. ArcSource Outdoor 16 MC Integral US (RGBA) - DMX protocol Version 1.1 Mode/Channel Value Function Type of control Red LEDs 0 - 255 Red LEDs saturation control (0-100%) proportional Green LEDs 0 - 255 Green LEDs saturation control (0-100%) proportional Blue LEDs...
  • Page 13: Arcsource Outdoor 16 Mc Integral Us (Smartwhite) - Dmx Protocol

    ArcSource Outdoor 16 MC Integral US 7. ArcSource Outdoor 16 MC Integral US (SmartWhite) - DMX protocol Version 1.1 Mode/Channel Value Function Type of control Warm white LEDs 0 - 255 Warm white LEDs saturation control (0-100%) proportional Cool white LEDs 0 - 255 Cool white LEDs saturation control (0-100%) proportional...
  • Page 14: Control Menu Map

    ArcSource Outdoor 16 MC Integral US 9. Control menu map Default settings=Bold print Menu Level 1 Menu Level 2 Menu Level 3 Menu Level 4 Menu Level 5 Menu Level 6 DMXA Set DMXA 0001-0512 0001 InFo POn Time. Total Reset DMX In 0-255...
  • Page 15 ArcSource Outdoor 16 MC Integral US Menu Level 1 Menu Level 2 Menu Level 3 Menu Level 4 Menu Level 5 Menu Level 6 On/Off T On, Off Contrast 0-100% Backlight 0-100% Temp Uni °C, °F I Ef Pos 0-255 Green 0-255 Blue...
  • Page 16 ArcSource Outdoor 16 MC Integral US Menu Level 1 Menu Level 2 Menu Level 3 Menu Level 4 Menu Level 5 Menu Level 6 Pr Edit Prog 1 Step 01 Prg End 1-40 0-255 Prog 3 Step 40 F.Tim. 0-25.5 sec Copy Special rdM Low...
  • Page 17 Menu Level 5 Menu Level 6 Sw Upd No/Yes RDM menu (e.g. for the Robe Universal Interface WTX, because this device cannot display 2-row display of the ArcSource Outdoor 16 MC Integral US) Default settings=Bold print Menu Level 1 Menu Level 2...
  • Page 18 ArcSource Outdoor 16 MC Integral US Menu Level 1 Menu Level 2 Menu Level 3 Menu Level 4 Menu Level 5 Menu Level 6 In.Po. GrEn bLuE WhIt C.vhE Stro dimr F.dim SAVE dF. SE. Man. M. 0-255 Dim F 0-255 tESt St.
  • Page 19 ArcSource Outdoor 16 MC Integral US Menu Level 1 Menu Level 2 Menu Level 3 Menu Level 4 Menu Level 5 Menu Level 6 F.tim. 0-25.5 COPy SPEC rdM. L. rdM. H. t. LEd rGbV Si. Co. SM. Vh. rAdI. Stat UnLi I.bLi.
  • Page 20: Fixture Menu

    ArcSource Outdoor 16 MC Integral US 10. Fixture menu The control panel menu allows to set the fixture according to your needs, obtain information on its operation and manual control of all effects. The four control buttons on the front have the following functions: - ESCAPE button-leaves menu without saving changes.
  • Page 21: Personality

    ArcSource Outdoor 16 MC Integral US Measuring points: Led-temperature on the PCB with LEDs Board- temperature on the control board of LEDs Note: The ambient temperature should not exceed 40°C. The temperatures can be displayed in either °C or °F units - see option “tEM.U“ in the menu “Pers“. Sw Ver ---Software Versions.
  • Page 22: Manual Mode

    ArcSource Outdoor 16 MC Integral US Display. --- Display adjusting. This function allows you to change the display settings. This function turns the display by 180°. Turn - This function allows you to keep the display permanent on or turn it off two minutes On/Off T - after last pressing any button on the control panel.
  • Page 23: Special Functions

    ArcSource Outdoor 16 MC Integral US 3. Use the UP/DOWN buttons to select “ Auto Run“ item. 4. Press the ENTER button. 5. Use the UP/DOWN buttons to select desired program. 6. Press the ENTER button to confirm the choice. Pr Play --- Playing program.
  • Page 24 - Flash cable RS232/DMX P/N13050624 (if you want to use a serial port of PC) - Robe Universal Interface or Robe Universal interface WTX (if you want to use an USB port of PC) After the software updating the fixture will be set to default (factory) values.
  • Page 25 If you use the Robe Universal Interface, connect a USB port of your computer with the Robe Universal Interface by means of the USB cable and DMX input of the fixture with the DMX output of the Robe Universal Interface via a DMX cable.
  • Page 26: Rdm

    Discovery command SET command GET command DISC_UNIQUE_BRANCH DISC_MUTE DISC_UN_MUTE DEVICE_INFO SUPPORTED_PARAMETERS SOFTWARE_VERSION_LABEL DMX_START_ADDRESS IDENTIFY_DEVICE DEVICE_MODEL_DESCRIPTION MANUFACTURER_LABEL DEVICE_LABEL SENSOR_DEFINITION SENSOR_VALUE DISPLAY_LEVEL DEVICE_RESET DMX_PERSONALITY DMX_PERSONALITY_DESCRIPTION STATUS_MESSAGES STATUS_ID_DESCRIPTION DEVICE_HOURS Please, see the Robe Universal Interface user manual for detail description of RDM operation.
  • Page 27: Technical Specifications

    ArcSource Outdoor 16 MC Integral US 12. Technical specifications Power supply • Electronic auto-ranging • Input voltage: 120 - 277V AC, 50-60 Hz • Max. power consumption: 42W (power factor=0.75, I=0.24A at 230V) • Inrush current: 13.4 Apk (at 120V AC) 27.9 Apk (at 230V AC) 31.0 Apk (at 230V AC) Optic &...
  • Page 28 ArcSource Outdoor 16 MC Integral US Dimensions ArcSource Outdoor 16 MC Integral US mm [inch] Top hat...
  • Page 29 ArcSource Outdoor 16 MC Integral US Half top hat Tilt adjustment range • 90°...
  • Page 30: Cleaning And Maintenance

    Maintenance and service operations are only to be carried out by a qualified person. Should you need any spare parts, please use genuine parts. Specifications are subject to change without notice. January 10, 2020 Made in ROBE Lighting s.r.o., Palackého 416, 757 01 Valašské Meziříčí, Czech Republic...

This manual is also suitable for:

Arcsource outdoor 16 mc integral smartwhite usArcsource outdoor 16 mc integral sinqlecolour usArcsource outdoor 16 mc integral rgba us

Table of Contents