Set Up Baud Rates And Modem/Slip/Ppp Parameters; Table 5. Alarm Output Options - Canoga Perkins 2346 User Manual

T3 fiber optic modem
Table of Contents

Advertisement

2. At the Alarm Output Configuration screen, type the number for an alarm and press <Enter>. See
Table 5.
3. Press <Space> to cycle to Enabled or Disabled and press <Enter>.
4. To return to the Main Menu, press <Esc>.
These selections do not affect how the CIM Major and Minor LEDs report alarms.

Table 5. Alarm Output Options

Alarm
2) LOS/CLS
3) SQL
4) Configuration
5) Power/Fan
6) Power-On Self Test Modem failed when power was turned on; default is Major
7) BERT
Note: The Bit Error Rate Test (BERT) sends a continuous 127-bit sequence within the optical data
stream to check for bit errors while the optical signal remains in sync.

Set Up Baud Rates and Modem/SLIP/PPP Parameters

Although the default values for the communication parameters meet requirements for most systems,
you may need to change them for your particular situation.
To reset the VT100 baud rate, follow these steps:
1. At the Main Menu, type
2. At the Utilities menu, type
cycle between 9600 and 19200 bps.
3. To return to the Main Menu, press <Esc>.
To access the Modem/SLIP/PPP Configuration menu, follow these steps:
1. At the Main menu, type
2. At the Utilities menu, type
3. To select the baud rate for the serial port, type
<Enter>, then press <Space> to cycle through the baud rate options; options include 9600, 19200,
38400, 57600, or 115200 bps.
EdgeAccess Universal Chassis System
When enabled, sends an alarm if. . .
Loss of Signal (electrical)/Composite Loss of Signal (optical); one or
both received signals fail; default is Off
Squelch occurs (for received signal); default is Off
The 2346 is set up incorrectly or the local and remote software versions
do not match; default is Off
Power is low or fan is off; default is Minor
Bit Error Rate Test (BERT) detects data errors; for details on BERT
results, see page 3-12; default is Off
, "Utilities," and press <Enter>.
4
, "VT100 Baud Rate," and press <Enter>, then press <Space> to
3
, "Utilities," and press <Enter>.
4
, "Modem/SLIP/PPP Configuration," and press <Enter>.
4
2346 T3 Modem
, "Modem/SLIP/PPP Configuration," and press
4
3-7

Hide quick links: