EPSON WorkForce 600/EPSON Stylus OFFICE TX600FW/BX600FW/EPSON Stylus SX600FW/ME OFFICE 700FW
After releasing the Timing Belt, temporarily secure the belt to the
C A U T I O N
Cartridge Cover with a tape or the like so as not to allow the grease
to come in contact with the Timing Belt. Contaminating the belt
with grease can result in malfunction of the printer.
3.
Loosen the tension of the Timing Belt by pressing the Driven Pulley Holder in
the direction of the arrow as shown in the figure, and release the Timing Belt
from the pinion gear of the CR Motor.
Do not damage the pinion gear of the CR Motor.
C A U T I O N
4.
Remove the screws (x2) that secure the CR Motor, and remove the CR Motor.
Driven Pulley
Timing Belt
Holder
Figure 4-77. Removing the CR Motor (2)
DISASSEMBLY/ASSEMBLY
CR Motor
Pinion Gear
2
1
C.P. 3x4, F/Zn-3C (4±1kgfcm)
Disassembling the Printer Mechanism
Be sure to install the CR Motor so that the groove on it faces
downward.
Figure 4-78. CR Motor
Tighten the screws in the order given in
Make sure that there is no gap between the CR Motor and the
Main Frame.
Whenever the CR Motor is removed/replaced, the required
A D J U S T M E N T
R E Q U I R E D
lubrication must be carried out.
Chapter 6 " MAINTENANCE" (p.163)