EPSON WorkForce 600/EPSON Stylus OFFICE TX600FW/BX600FW/EPSON Stylus SX600FW/ME OFFICE 700FW
When installing the PF Motor Assy, pay attention to the
following instructions.
Insert the dowels (x2) on the Base Frame into the positioning
holes (x2) of the PF Motor Assy as shown in
Route the PF Motor Connector Cable as shown in the figure
below.
PF Motor connector cable
Figure 4-75. Routing the PF Motor Connector Cable
Tighten the screws in the order given in
DISASSEMBLY/ASSEMBLY
Figure.
4-74.
170mm
Figure.
4-74.
Disassembling the Printer Mechanism

4.5.12 CR Motor

Parts/Components need to be removed in advance
Scanner Unit/ADF Unit/Upper Housing /Hinge/Middle Cover/Printer Mechanism/
Card Slot Cover/Main Board Unit/Left Frame/Front Frame/Right Frame
Removal procedure
1.
Turn the Spur Gear 51.5 to release the Carriage Lock, and move the CR Unit
to the center.
(Refer to 4.5.1 Printhead Step1 (p109))
Be careful not to damage the CR Motor cable when releasing the
C A U T I O N
cable from the hooks of the Main Frame.
2.
Release the CR Motor cable from the notches (x3) of the Base Frame and the
hooks (x3) of the Main Frame, and then pull out the cable through the hole of
the Base Frame.
Hook
Notch
Hole
Figure 4-76. Removing the CR Motor (1)