BURNER & PILOT FLAME CHECK
A periodic check of the flames should be made. The pilot flame should always be present
when the gas logs are in operation. See figure below.
Rear Flames: The flames at the rear should be yellow in color, and should extend about 4" to
5" above the large rear log for natural gas logs and about 6" for propane (LP) gas log sets.
Front Flame: The flame should be blue in color and sweeping from bottom of the middle log
and producing a red glow on the lugs (burn area). NOTE: Allow approximately ten (10)
minutes to achieve proper glow on middle log.
EMBERVISION 100
24" PINE
LOG SET
EMBERVISION 200
30" OAK
LOG SET
WHEN USED AS A HEATING APPLIANCE
The heat output into the room can be controlled by the position of the flue damper, when used
as "vented gas logs". See Section VI - Vented Models.
The heat output is controlled by the "ON/OFF" switch or wall thermostat, not by the control
knob. The gas logs are either "ON" or "OFF".
The gas logs may be used as non-vent gas logs only where permitted by local state and city
codes. If non-vent gas logs are not permitted, then the fireplace vent area required by
local codes must be met. In the absence of local codes, the latest edition of the National
Fuel Gas Code (ANSI Z223.1) must be met.
PROPER BURNER FLAME

HEAT OUTPUT

Page 15
PROPANE
NATURAL
PROPER PILOT
FLAME