AFTER MARKET MOBILE HOME INSTALLATION
THIS APPLIANCE MAY BE INSTALLED IN AN AFTERMARKET*, PERMANENTLY
LOCATED, MANUFACTURED (MOBILE) HOME, WHERE NOT PROHIBITED BY
LOCAL CODES. *After Market: Completion of sale, not for the purpose of resale from the
manufacturer.
THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON
THE RATING PLATE. THIS APPLIANCE IS NOT CONVERTIBLE FOR USE WITH
OTHER GASES.
NOTE: For mobile home installation follow "Residential Installation", Section II, page 4.
PRODUCING ADEQUATE AIR FOR
COMBUSTION AND VENTILATION
NOTE: This heater shall not be installed in a room or space unless the required volume of indoor
combustion air is provided by the method in the National Fuel Gas Code, ANSIZ223.1/NFPA 54,
the International Fuel Gas Code, or applicable codes.
The National Fuel Gas Code, ANSI Z223.1/NFPA 54 defines unusually tight construction or
unconfined space as a space whose volume is less than 50 cubic feet per 1,000 BTU per hour
3
(4.8m
per kw) of the aggregate input rating of all appliances installed in that space and an
unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 BTU per hour
3
(4.8m
per kw) of the aggregate input rating of all appliances installed in that space. Rooms
communicating directly with the space in which the appliances are installed, through openings
not furnished with doors, are considered a part of the unconfined space.
"WARNING: IF THE AREA IN WHICH THE HEATER MAY BE OPERATED DOES
NOT MEET THE REQUIRED VOLUME FOR INDOOR COMBUSTION AIR,
COMBUSTION AND VENTILATION AIR SHALL BE PROVIDED BY ONE OF THE
METHODS DESCRIBED IN THE NATIONAL FUEL GAS CODE, ANSI Z223.1/NFPA 54,
THE INTERNATIONAL FUEL GAS CODE, OR APPLICABLE CODES."
"WARNING: IF THE AREA IN WHICH THE HEATER MAY BE OPERATED IS
SMALLER THAN THAT DEFINED AS AN UNCONFINED SPACE OR IF THE
BUILDING IS OF UNUSUALLY TIGHT CONSTRUCTION, PROVIDE ADEQUATE
COMBUSTION AND VENTILATION AIR BY ONE OF THE METHODS DESCRIBED
IN THE NATIONAL FUEL GAS CODE, ANSI Z223.1/NFPA 54 AIR FOR COMBUSTION
AND VENTILATION, OR APPLICABLE LOCAL CODES."
Unusually tight construction is defined as construction where:
a) Walls and ceilings exposed to the outside atmosphere have a continuous water vapor retarder
with a rating of 1 perm (6 x 10
b) Weather stripping has been added on openable windows and doors, and
c) Caulking or sealants are applied to areas such as joints around window and door frames,
between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations
for plumbing, electrical, and gas lines, and at other openings.
SECTION IV
SECTION V
-11
2
kg per pa-sec-m
) or less with openings gasketed or sealed, and