New Buck Corporation EMBER VISION 100 SERIES Installation Instructions Manual page 35

Vent-free or vented 30”(oak) gas log set vent-free or vented 24”(oak or pine) gas log set for natural or liquid petroleum (l.p.) with optional heat shield model 19hs
Table of Contents

Advertisement

IF YOU SMELL GAS:
* SHUT OFF GAS SUPPLY
* DO NOT TRY TO LIGHT APPLIANCE
* DO NOT TOUCH ANY ELECTRICAL SWITCH; DO NOT USE ANY
PHONE IN YOUR BUILDING
* IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR'S
PHONE. FOLLOW THE GAS SUPPLIER'S INSTRUCTIONS.
* IF YOU CANNOT REACH YOUR GAS SUPPLIER, CALL THE FIRE
DEPARTMENT.
IMPORTANT: Operating heater where impurities in the air exist may create odors. Cleaning
supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc.
create fumes. These fumes may mix with combustion air and create odors.
OBSERVED
PROBLEM
Heater produces a clicking/ticking
noise just after burner is lit or shut
off
Heater produces unwanted odors
Heater shuts off in use
(ODS operates)
Gas odor even when control knob
is in OFF position
WARNING
POSSIBLE
CAUSE
1. Metal expands while heating
or contracts while cooling
1. Heater burning vapors from
paint, hair spray, glues, etc.
(See "Important" above)
2. Low fuel supply
3. Gas leak (See "WARNING"
above)
1. Not enough fresh air is
available
2. Low line pressure
3. ODS/PILOT is partially
clogged
1. Gas leak (See "WARNING"
above)
2. Control valve defective
Page 31
SOLUTION
1. This is common with most
heaters. If noise is
excessive, contact a
qualified service person.
1. Ventilate room. Stop using
odor causing products while
heater is running.
2. Refill supply tank.
3. Locate and control all leaks.
See "Checking Gas
Connections".
1. Open window/door for
ventilation
2. Contact local propane
company
3. Clean ODS/PILOT
1. Locate and correct all leaks
(see Checking Gas
Connections)
2. Replace control valve

Advertisement