Clearances; Gas Connection - New Buck Corporation EMBER VISION 100 SERIES Installation Instructions Manual

Vent-free or vented 30”(oak) gas log set vent-free or vented 24”(oak or pine) gas log set for natural or liquid petroleum (l.p.) with optional heat shield model 19hs
Table of Contents

Advertisement

"WARNING:
THIS APPLIANCE IS FOR INSTALLATION ONLY IN A SOLID FUEL
BURNING MASONRY OR UL127 FACTORY BUILT FIREPLACE OR IN A LISTED
VENTLESS FIREBOX ENCLOSURE.
IT HAS BEEN DESIGN CERTIFIED FOR THESE INSTALLATIONS. EXCEPTION: DO
NOT INSTALL THIS APPLIANCE IN A FACTORY BUILT FIREPLACE THAT
INCLUDES INSTRUCTIONS STATING IT HAS NOT BEEN TESTED OR SHOULD NOT
BE USED WITH UNVENTED GAS LOGS."
To ensure a safe installation into an existing solid fuel burning fireplace, the following instructions
must be carefully followed.
NOTE: Gas control knobs are located on right side facing unit.
1) Side wall Minimum Clearances:
Clearance from the right and left side of the fireplace opening to any adjacent
combustible wall should not be less than 4".
2) Ceiling Clearances:
The ceiling height should not be less than 42" from the top of the fireplace opening.
3) Mantel Minimum Clearances:
For clearances from top of heater to mantel or mantel supports see Figure 1.
4) Front Minimum Clearances:
No objects should be placed within 24" from the front of the fireplace opening.
MINIMUM FIREPLACE DIMENSIONS FOR EMBER VISION 100 AND 200 SERIES LOG
SET MANUFACTURED BY NEW BUCK CORPORATION FOR SOLID FUEL BURNING
FIREPLACE OR MASONRY FIREPLACE AND PREFAB OR MANUFACTURED
FIREPLACES.
HEIGHT OF
OPENING
MODEL 100
E.V. 24" Logs
17"
MODEL 200
E.V. 30" Logs
17"
NOTE: When using logset with The Model 19HS heat shield see page 16 for clearances.
WARNING:
ANY CHANGE TO THIS HEATER OR ITS
DANGEROUS.
WARNING:
"Cutting any sheet metal parts of the solid-fuel burning fireplace or listed
ventless firebox enclosure in which the unvented fireplace insert (log set) is to be installed is
prohibited."
NOTE: "Smoke shelves, shields and baffles may be removed if attached by mechanical
fasteners." NOTE: "Refractory, glass doors, screen rails, screen mesh and solid-fuel log grates
(if applicable) can be removed from the fire place before installing the unvented fireplace
insert.
WARNING:
Any glass doors shall be fully opened when the appliance is in operation.
Check gas type. Use only the type of gas indicated on the valve rating plate. If the type of gas
listed on the plate is not your type of gas supply, DO NOT INSTALL. Contact your dealer for
proper model.
INSTALLATION AND CLEARANCES
WIDTH OF
OPENING
AT FRONT
32"
34"

GAS CONNECTION

WIDTH AT
REAR
26"
26"
Page 5
.
DEPTH OF
FIREPLACE
15"
15"
CONTROLS CAN BE