THIS HEATER MUST HAVE ADEQUATE AMOUNT OF AIR FOR PROPER
OPERATION. IF NOT, POOR FUEL COMBUSTION COULD RESULT. READ THE
FOLLOWING INSTRUCTIONS TO ENSURE PROPER AMOUNT OF AIR FOR THIS AND
OTHER FUEL-BURNING APPLIANCES IN YOUR HOME.
VENTILATION AIR FOR COMBUSTION
AND VENTILATION FROM OUTDOORS
Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent
openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items
directly to the outdoors. These spaces include attics and crawl spaces. Follow the National
Fuel Gas Code NFPA 54/ANSI Z223.1, Section 5.3, Air For Combustion and Ventilation for
required size of ventilation grills or ducts.
IMPORTANT:
Do not provide openings for inlet air into attic if attic has a thermostat-
controlled power vent. Heated air entering the attic will activate the power vent.
Outlet Air
Outlet Air
Inlet Air
WARNING
Ventilated Attic
Inlet Air
To Attic
Ventilated
Crawl Space
Figure 10
Page 24
To
Crawl
Space