DEFAULT RECIPE PARAMETERS
(Regular, Decaf, Brazil, Colombia, Costa Rica, Ethiopia, Guatemala, Kenya, Peru, Sumatra)
Recipe Setting
Volume
Bypass
Pre-Infusion
Pulse Brew
SmartWAVE
SmartWAVE Enabled
Drip Time
Freshness Time
Total Brew Time
SH TEMPERATURE

BREW LOCKOUT

This is a feature that allows the user to lock out all brewing functions until the water in the tank has reached the
specified READY TEMPERATURE.
1. Touch the BUNN logo for 2 seconds to enter SERVICE ACCESS.
2. Select the ADVANCED icon.
3. At the PASSWORD ENTRY screen, select ENTER (If a password is required, enter the code at this screen).
4. In the ADVANCED MENU screen, select the MACHINE SETTINGS icon.
5. Select the BREW SETTINGS icon.
6. With the Temperature screen present, locate the BREW LOCKOUT feature on the bottom-left of the screen.
Select the white text area so that a green check mark appears.
7. Select the white text area across from READY TEMP. Enter the desired READY TEMP on the numeric pad.
Note: Ready temperature will allow brewing to occur when the tank temperature reaches that value.
PROGRAMMING (cont.)
Small Batch
64.0 OZ / 1.9 L
0%
Disabled
Disabled
4
NO
1:00 (Min:Sec)
1:00 (Hr:Min)
2:36 (Min:Sec)
185ºF
Medium Batch
(Disabled by Default)
128 OZ / 3.8 L
20%
Disabled
Disabled
4
NO
1:30 (Min:Sec)
1:00 (Hr:Min)
4:03 (Min:Sec)
185ºF
9
Large Batch
192.0 OZ / 5.6 L
25%
Disabled
Disabled
4
NO
2:00 (Min:Sec)
1:00 (Hr:Min)
5:36 (Min:Sec)
185ºF