Base Sensor Test - Lexmark C78x Service Manual

Hide thumbs Also See for C78x:
Table of Contents

Advertisement

5061

BASE SENSOR TEST

Use the Base Sensor Test to determine that the sensors located inside the printer are operating correctly. The
following sensors can be checked using this test:
Input—In-Line Media Clear
Input—S2 Media Clear
Fuser Exit Media Clear
NarrowMedia Media Clear
K TMC Sensor Not Closed (black)
C TMC Sensor Not Closed (cyan)
M TMC Sensor Not Closed (magenta)
Y TMC Sensor Not Closed (yellow)
See
"Printer sensors" on page 5-3
locations (cyan, magenta and yellow)" on page 5-4
on page
5-5.
CAUTION
These sensors are near high voltage terminals to the print cartridge. Use a nonconducting
item to toggle these switches and not your hand.
To run the Base Sensor Test.
1.
Select Base Sensor Test from BASE SENSOR TEST in the Diagnostics mode.
2.
Select the sensor to test.
Open, Clear, Closed, or Not Closed may be displayed, depending on the sensor.
3.
Manually toggle the sensors by hand to verify that each sensor switches from open to closed.
3-24
Service Manual
for locations for these sensors. See
or
"Cartridge contact assembly pin locations (black)"
"Cartridge contact assembly pin

Advertisement