5061
Acoustics
All measurements are made in accordance with ISO 7779 and conform with ISO 9296.
Status (at 1 Meter average sound
pressure)
Printing at 4800 CQ
Idle (standby)
Duplex models—printing simplex
Duplex models—printing duplex
Duplex models—idle
Environment
Printer Temperature and Humidity
•
Operating
–
Temperature: 60 to 90° F (15.6 to 32.3° C)
–
Relative humidity: 8 to 80%
–
Maximum wet bulb temperature: 73° F (22.8° C)
–
Altitude: 10,000 ft. (0 to 3,048 meters)
–
Atmospheric pressure: 74.6 kPa
•
Power off
–
Temperature: 50 to 110° F (10 to 43.3° C)
–
Relative humidity: 8 to 80%
–
Maximum wet bulb temperature: 80.1° F (26.7° C)
–
Altitude: 10,000 ft. (0 to 3,048 meters)
–
Atmospheric pressure: 74.6 kPa
•
Ambient operating environment*
–
Temperature: 60 to 90° F (15.6 to 32.2° C)
–
Relative humidity: 8 to 80%
•
Storage and shipping (packaged printer) with or without print cartridge
Temperature: -40 to 110° F (-40 to 43.3° C)
•
Print cartridge
Temperature: -40 to 110° F (-40 to 43.3° C)
*In some cases, performance specifications (such as paper OCF, EP cartridge usage) are measured at an
ambient condition.
1-6
Service Manual
Lexmark
Lexmark
C770n
C772n
52 dBA
52 dBA
34 dBA
34 dBA
52 dBA
52 dBA
52 dBA
52 dBA
34 dBA
34 dBA
Lexmark
Lexmark
C780n
C782n
52 dBA
53 dBA
30 dBA
30 DBA
52 dBA
53 dBA
60 dBA
60 dBA
30 dBA
30 DBA